Settings; Initial Directions; Internet Connection; Communication Ports - WEG Cassia X1000 Installation And Operation Manual

Table of Contents

Advertisement

Available languages

Available languages

5 SETTINGS

5.1 INITIAL DIRECTIONS

For your WEG Motor Scan to communicate with the X1000 Gateway, its firmware version must be higher than
or equal to 2.0.0.
The X1000 Gateway can operate with up to 100 WEG Motor Scan sensors simultaneously.
The signal range depends on factors such as physical barriers between the gateway and sensors, signal
interference and proper installation. It is estimated that the signal range in industrial environments can reach 30
meters, and in the open field (without interference or barriers) 50 meters.
Sensors operating at the distance limit may have their measurement routing impaired.

5.2 INTERNET CONNECTION

5.2.1 Communication Ports

Before starting to set the X1000 Gateway, check that the firewall of the network to which it will be connected has
the port and destination releases of the tables below.

5.2.2 Infrastructure

The gateway requires an internet access port for setup and data upload of the Weg Motor Scan sensors. It can
be connected to the Internet in four ways, as described below.
Table 5.1: List of ports to be released in the firewall
Protocol
Port
TCP
1883
TCP
433
TCP
9999
UDP
6246
UDP
6247
TCP
8001
TCP
8883
UDP
53
TCP
80
Table 5.2: List of destinations to be released in the firewall
Destination
cassia.weg.net
ports.ubuntu.com
broker.app.wnology.io
Direction
Output
Output
Input/Output
Output
Output
Input/Output
Input/Output
Output
Output
IP
52.116.206.26
91.189.91.38
146.148.110.247
Gateway Cassia X1000 | 11
Settings

Advertisement

Table of Contents
loading

Table of Contents