Timer Operation; Noise Reduction; Multi Space Mode - Bosch Climate 6100i Operation Manual

Air/air heat pump
Hide thumbs Also See for Climate 6100i:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

The spot airflow mode used with full power mode or plasmacluster mode
at the same time in order to concentrate the respective operating mode
to the required area.
▶ Press the Spot key when full power mode or plasmacluster mode is
active.
This mode is not available in automatic mode.

3.10.3 Timer operation

Set 1-2-3-5h off timer
When the 1-2-3-5h off timer is set, the unit will automatically turn off
after the set hours.
▶ Press the
button to set the desired time.
The orange timer lamp
on the unit will light up.
The remaining time will be indicated on the remote control in 1-hour
increments.
To cancel the timer:
▶ Press the Set/C button or the
The orange timer lamp
on the unit will turn off.
The current clock time will be displayed on the remote control.
The 1-2-3-5h off timer has priority over the off/on timer. If the 1-2-3-5h
off timer is set while the unit is not operating, the unit will start operating
and stop after the set period of time.
Set off timer
▶ Press the
button.
The off timer indicator will blink.
▶ Press the . or / button to set the desired time.
(The time can be set in 10-minute increments or decrements.)
▶ Press the Set/C button.
The orange timer lamp
on the unit will light up.
When the off timer is set, the temperature setting is automatically
adjusted to prevent the room from becoming excessively warm or cool,
for example while you sleep (auto sleep function).
In cooling mode:
• One hour after the time operation begins, the temperature setting
rises 1 °C higher than the original temperature setting.
In heating mode:
• One hour after the timer operation begins, the temperature setting
drops 3 °C lower than the original temperature setting.
Set on timer
▶ Press the
button.
The on timer indicator will blink.
▶ Press the . or / button to set the desired time.
(The time can be set in 10-minute increments or decrements.)
▶ Press the Set/C button.
The orange timer lamp
on the unit will light up.
Climate 6100i/8100i – 6721821568 (2020/11)
0010030499-001
button.
The unit will turn on prior to the set time. This allows the room to reach
the desired temperature by the programmed time (awaking function).
Cancel all timers
▶ Press the Set/C button.
The orange timer lamp
on the unit will turn off.
The current clock time will be displayed on the remote control.
Combine on timer and off timer
On timer and off timer can be set at the same time. Either timer can be
programmed to activate prior to the other
▶ Set the on timer and off timer.
The settings will be automatically combined.
Example:
• Current time: 21:00
• Off timer at 11:00 p.m.
• On timer at 7:00 a.m.
An arrow (
or
) next to the timer indicator shows which timer will
activate first.
You can not program the on timer and off timer to operate the unit at
different temperatures or other settings.

3.10.4 Noise reduction

This function reduces the noises emitted by the outdoor unit when it is in
operation. This is particularly advantageous at night, if you need to show
consideration for your neighbours.
▶ During operation, press the
Exiting the function:
▶ Press the
button again.
When noise reduction is active, a number of operating modes may not
reach their full performance potential. The sound pressure level is not
reduced if it has already dropped low enough at stable condition.

3.10.5 Multi space mode

Multi space mode cannot be activated during auto mode, the button is
disabled.
The unit will operate to cool or warm multiple rooms in a well insulated
house by pressing this button.
▶ During cooling or heating operation, press the
– In heating mode, the remote control displays
– In cooling mode, the remote control displays
The louver angle changes to the position for long distance delivery of
air. The remote control displays
To cancel multi space mode:
▶ Press the
button again.
The unit will operate at extra high fan speed for long distance delivery of
conditioned air. After 15 minutes the unit shifts to high fan speed.
The Fan button is disabled during this operation mode.
Operation
button.
button.
.
.
and
.
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents