Advertisement

Quick Links

Instructions for use
MASTERtorque LUX M9000 L COLOR -
1.007.9900
MASTERtorque LUX M9000 L COLOR -
1.007.7100

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MASTERtorque LUX M9000 L COLOR 1.007.9900 and is the answer not in the manual?

Questions and answers

Summary of Contents for KaVo MASTERtorque LUX M9000 L COLOR 1.007.9900

  • Page 1 Instructions for use MASTERtorque LUX M9000 L COLOR - 1.007.9900 MASTERtorque LUX M9000 L COLOR - 1.007.7100...
  • Page 2 Distributed by: Manufacturer: KaVo Dental GmbH Kaltenbach & Voigt GmbH Bismarckring 39 Bismarckring 39 D-88400 Biberach D-88400 Biberach Phone +49 7351 56-0 www.kavo.com Fax +49 7351 56-1488...
  • Page 3: Table Of Contents

    Automated Drying ....................21 7.4 Care products and systems - Servicing................22 7.4.1 Servicing with KaVo Spray ................... 22 7.4.2 Servicing with KaVo QUATTROcare PLUS .............. 22 7.4.3 Care with KaVo SPRAYrotor ................. 23 7.4.4 Servicing with KaVo QUATTROcare ..............24 7.5 Packaging ........................
  • Page 4 Instructions for use MASTERtorque LUX M9000 L COLOR - 1.007.9900 MASTERtorque LUX M9000 L COLOR - 1.007.7100 Table of contents 8 Tools and consumables ...................... 26 9 Terms and conditions of warranty ..................27 4 / 30...
  • Page 5: User Instructions

    1 User instructions 1 User instructions Dear User Congratulations on purchasing this KaVo quality product. By following the in- structions below you will be able to work smoothly, economically and safely. © Copyright by KaVo Dental GmbH KaVo Technical Service...
  • Page 6 Instructions for use MASTERtorque LUX M9000 L COLOR - 1.007.9900 MASTERtorque LUX M9000 L COLOR - 1.007.7100 1 User instructions Please note the electronic instructions for use Note: observe accompanying documents EAC conformity mark (Eurasian Conformity) GOST R certification Transportation and storage conditions (Temperature range) Transportation and storage conditions (Air pressure)
  • Page 7: Safety

    Instructions for use MASTERtorque LUX M9000 L COLOR - 1.007.9900 MASTERtorque LUX M9000 L COLOR - 1.007.7100 2 Safety | 2.1 Infection hazard 2 Safety The instructions for use are a component of the product and must be read care- fully prior to use and be accessible at all times.
  • Page 8: Accessories And Combination With Other Equipment

    Repairs, servicing and safety checks may only be performed by trained service personnel. The following persons are authorised to do this: ▪ Service technicians of KaVo branches after the appropriate product training ▪ Service technicians of KaVo authorised dealers after the appropriate product...
  • Page 9: Product Description

    Instructions for use MASTERtorque LUX M9000 L COLOR - 1.007.9900 MASTERtorque LUX M9000 L COLOR - 1.007.7100 3 Product description | 3.1 Purpose – Proper use 3 Product description MASTERtorque COLOR MASTERtorque LUX M9000 L COLOR (chocolate brown) Mat. no. 1.007.9900 MASTERtorque LUX M9000 L COLOR (anthracite) Mat.
  • Page 10: Technical Specifications

    Instructions for use MASTERtorque LUX M9000 L COLOR - 1.007.9900 MASTERtorque LUX M9000 L COLOR - 1.007.7100 3 Product description | 3.2 Technical Specifications 3.2 Technical Specifications Drive pressure 2.1 to 4.2 bar (30 to 61 psi) Recommended drive pressure 2.8 bar (41 psi) Return air pressure <...
  • Page 11: Start Up And Shut Down

    Instructions for use MASTERtorque LUX M9000 L COLOR - 1.007.9900 MASTERtorque LUX M9000 L COLOR - 1.007.7100 4 Start up and shut down | 4.1 Mounting the MULTIflex (LUX) / MULTIflex LED coupling 4 Start up and shut down WARNING Hazard from non-sterile products.
  • Page 12: Checking The Pressures

    Instructions for use MASTERtorque LUX M9000 L COLOR - 1.007.9900 MASTERtorque LUX M9000 L COLOR - 1.007.7100 4 Start up and shut down | 4.3 Checking the pressures 4.3 Checking the pressures NOTICE Contaminated or moist compressed air at the compressed air connec- tion Premature wear ▶...
  • Page 13: Operation

    Instructions for use MASTERtorque LUX M9000 L COLOR - 1.007.9900 MASTERtorque LUX M9000 L COLOR - 1.007.7100 5 Operation | 5.1 Attaching the medical device 5 Operation Note At the beginning of each workday, the water-conducting systems should be rinsed for at least 2 minutes (without transmission handpieces being at- tached) and if there is a risk of contamination from reflux or back suction, the system may also need to be rinsed for 20 to 30 seconds after each patient.
  • Page 14: Removing The Cutter Or Grinder

    Instructions for use MASTERtorque LUX M9000 L COLOR - 1.007.9900 MASTERtorque LUX M9000 L COLOR - 1.007.7100 5 Operation | 5.4 Removing the cutter or grinder CAUTION Use of dental burs or diamond grinders with worn or damaged shafts. Risk of injury, tool may fall out during treatment. ▶...
  • Page 15 Instructions for use MASTERtorque LUX M9000 L COLOR - 1.007.9900 MASTERtorque LUX M9000 L COLOR - 1.007.7100 5 Operation | 5.4 Removing the cutter or grinder ▶ After the dental bur or diamond grinder has stopped rotating, firmly press the press-button with your thumb and simultaneously pull out the dental bur or diamond grinder.
  • Page 16: Troubleshooting

    ▶ Do not use Vaseline or other grease or oil. Note The O-rings on the coupling may only be lubricated with a cotton ball wetted with KaVo Spray. ▶ Press the O-ring between your fingers to form a loop. ▶ Push the O-ring to the front, and remove it.
  • Page 17 Instructions for use MASTERtorque LUX M9000 L COLOR - 1.007.9900 MASTERtorque LUX M9000 L COLOR - 1.007.7100 6 Troubleshooting | 6.3 Changing the water filter CAUTION Hazard from insufficient spray water. Insufficient spray water can cause the medical device to overheat and damage the tooth.
  • Page 18: Reprocessing Steps In Accordance With Iso 17664

    ▶ Brush off under flowing tap water. 7.2.2 Manual cleaning - internal Validated internal cleaning (removal of residual protein) can be accomplished with KaVo CLEANspray. ▶ Cover the medical device with the KaVo Cleanpac bag, and place it on the corresponding care adapter. 18 / 30...
  • Page 19: Manual Disinfection - External

    See also: 2 7.2.5 Manual drying, Page 20 Note KaVo CLEANspray and KaVo DRYspray for manual interior cleaning are only available in the following countries: Belgium, Denmark, Germany, Finland, France, United Kingdom, Italy, Latvia, Lithuania, Luxembourg, Netherlands, Norway, Austria, Poland, Portugal, Sweden, Switzerland, Spain and the Czech Republic.
  • Page 20: Manual Disinfection - Internal

    KaVo with respect to the compatibility of materials (e.g. WL-cid / made by ALPRO). ▶ Cover the medical device with the KaVo CLEANpac bag, and place it on the corresponding care adapter. ▶ Hold the can vertically.
  • Page 21: Automated Reprocessing

    Note Please observe the instructions for use of the thermodisinfector. ▶ In order to prevent impairment of the KaVo medical device, make sure that the inside and outside of the device is dry after the end of the cycle. ▶ Remove any residual liquids with KaVo DRYspray.
  • Page 22: Care Products And Systems - Servicing

    ▶ Remove the tool from the medical device. ▶ Cover the medical device with the KaVo CLEANpac bag, and place it on the corresponding care adapter. ▶ Press the spray key for 1 to 2 seconds.
  • Page 23: Care With Kavo Sprayrotor

    See also: 2 Instructions for use KaVo QUATTROcare PLUS Servicing of the clamping chuck KaVo recommends servicing the chuck system once a week using the chuck servicing program integrated in the device. Note Handpieces must be taken off the service couplings before the chuck service can be started and performed.
  • Page 24: Servicing With Kavo Quattrocare

    (no validated cleaning of the interior according to German Robert Koch Institute (RKI) requirements) KaVo recommends servicing the product as part of the reprocessing after each use, i.e. after each cleaning, disinfection, and before each sterilisation. ▶ Remove the tool from the medical device.
  • Page 25: Sterilisation

    Damage to product. ▶ Immediately remove the product from the steam steriliser after the steril- isation cycle. The KaVo medical device has a maximum temperature resistance up to 138 ℃ (280.4 °F). Sterilisation parameters: Select a suitable procedure (depending on the available autoclave) from the fol- lowing sterilisation processes: ▪...
  • Page 26 Insert for turbine handpieces 0.411.9902 Cleanpac 10 units 0.411.9691 MULTIflex spray head (nozzle) 0.411.9921 Material summary Mat. no. Adapter KaVo MULTIflex for KaVo 1.007.1775 CLEANspray/ DRYspray CLEANspray/ DRYspray Starter set 1.007.0573 2116 P KaVo CLEANspray 2110 P 1.007.0579 KaVo DRYspray 2117 P 1.007.0580...
  • Page 27 24 months from the date of the invoice, subject to the following conditions: In case of justified complaints, KaVo will honour its warranty with a free re- placement or repair. Other claims of any nature whatsoever, in particular with respect to compensation, are excluded.

This manual is also suitable for:

Mastertorque lux m9000 l color 1.007.7100

Table of Contents