The connection piping must be suitably supported so as
not to bear on the appliance with its weight.
Plants filled with antifreeze or special legal provisions re-
quire the use of hydraulic disconnectors.
Flush the plant thoroughly before connecting the unit.
This cleaning process removes any residue, such as weld-
ing drops, slag, rust or other fouling from the pipes. These
substances may otherwise settle inside and cause the ap-
pliance to malfunction.
Hydraulic lines and joints must be thermally insulated.
Insulate the water distribution piping with polyethylene
Hydraulic connection diagram
A
Boiler
B
Domestic hot water consumers
C
High temperature (radiator) utilities
D
System utilities
1�
Expansion vessel 24 litres
2�
7-bar safety valve
3�
Thermostatic mixing valve (optional)
4�
High-temperature circulation pump P3 (optional)
5�
System circulation pump P2
6�
Hydraulic separator
7�
Y filter
8�
Plate exchanger
9�
Automatic relief valve
A
1
B
C
4
5
2
T1
3
6
15
20
17
18
T3
S2
19
foam or similar materials with a minimum thickness of 13
mm. Shut-off valves, elbows and various fittings must also
be adequately insulated.
Avoid partial insulation of the pipes.
Avoid over-tightening the pipes to avoid damage to the
insulation.
Carefully check that the insulation is tight, in order to pre-
vent the making and dripping of condensate.
Operating the unit without the water filter installed and
clean is forbidden.
10�
3-bar safety valve
11�
Collector with heating element (optional)
12�
P1 head pump circulation pump
13�
3-way valve
14�
Boiler relief valve
15�
Solar filling cock (optional)
16�
4 bar solar safety valve (optional)
17�
Pressure gauge (optional)
18�
Solar circuit pump PSO (optional)
19�
Solar serpentine
20�
Domestic hot water stainless steel coil
21�
Outdoor unit
22�
Solar panel
D
9
10
8
11
12
7
13
1
16
INSTALLATION
21
T4
22
S1
23