The lighting goes on and off when the speed levels are turned up
or the lighting cannot be switched on or off.
Possible cause: The speed mode of the decoder and the digital
control unit do not correspond. Example: The central is set to the
mode 28 speed levels, but the decoder to the mode 14 speed
levels. à Change the speed mode at the central and / or at the
decoder.
Problems with the RailCom area of the FD-R
§
The CV values cannot be read out.
Possible cause: RailCom is switched off. à Alter the value of
CV#29.
Possible cause: The settings of the function decoder area have not
been transferred into the RailCom area. à Program the RailCom
area with the data of the function decoder area.
Please note: When operating the FD-R
decoder, only the decoder´s settings are transferred via RailCom.
Only when the FD-R
address of it´s own, are it´s data transferred.
§
A combination of the FD-R
programmed together or the data cannot be read out from one of
the modules.
Possible cause: This malfunction occurs especially with older DCC
decoders. à In most cases you can sidestep this malfunction by
programming the RailCom area of the FD-R
main track programming. In case this does not work as well, you
should read out or program the RailCom area of the FD-R
the decoder individually. For that purpose interrupt the connection
to the rail connector of that module that is not going to be
programmed.