tams elektronik FD-R Basic Manual page 24

Railcom transmitter and function decoder
Table of Contents

Advertisement

English
Name of CVs /
Registers
Assignment of the function keys to the outputs
F0 forward on 33
F0 backward on 34
F1
F2
...
F12
Factory settings: AUX1 to be switched with F0, switched on at forward motion.
AUX2 to be switched with F0, switched on at backward motion.
Example: AUX2 to be switched with F5 à CV#39 = 2
Example: AUX1 and AUX2 to be switched with F6 à CV#40 = 3 (= 1+2)
Dimming of the outputs:
AUX1
AUX2
Dependant on the direction of motion
of the outputs
AUX1
AUX2
Example: Shunting light at AUX1 to be switched with F3 and at forward motion off
à CV#53 = 17 (= 16 + 1)
Keying ration of the flash lights
AUX1
AUX2
Page 52
CV-
Reg.
Input value
no.
no.
(Default)
08
0 ... 31 (1)
09
0 ... 31 (2)
35
10
0 ... 31 (0)
36
11
0 ... 31 (0)
...
...
0 ... 31 (0)
46
21
0 ... 31 (0)
49
22
1 ... 64 (64)
50
23
1 ... 64 (64)
53
26
0 ... 63 (0)
54
27
0 ... 63 (0)
61
34
0...255 (255) on-/off states of the lighting
62
35
0...255 (255) 0
Remarks and Tips
Numerical value*
Assigned output:
AUX1
AUX2
= Reducing the voltage
applied to the output A.
value of "1" corresponds to
the minimum, "64" to the
maximum voltage.
Numerical value*
independent of direction
AUX off at forward motion 1
AUX off at backward motion 2
Shunting light AUX at F3 16
Shunting light AUX at F4 32
= Phase´s length of the
à lighting off
128à regular flashing light
255à continuous lighting
Basic
FD-R
1
2
0

Advertisement