SYSTEM CONFIGURATION
System number 2
Parameter configuration
Description
Select system configuration
Enable zone management
NOT = Disabled
YES = Enabled
System type (table 1)
Mixing valve ZONE 1
Type of mixing valve
1= 0-10V
HEATING compensation curve ZONE 1
Enable compensation curve NOT = Disabled YES = Enabled
Heating compensation curve number
Enable room temperature influence
NOT = Disabled
YES = Enabled
Room Authority
MINIMUM set point limit for curve
MAXIMUM set point limit for curve
COOLING compensation curve ZONE 1
Enable compensation curve NOT = Disabled YES = Enabled
Maximum temperature set point limit in cooling mode (Tm1)
Minimum outside temperature corresponding to max. outlet
temperature (Te1)
Minimum temperature set point limit in cooling mode (Tm2)
Maximum outside temperature corresponding to min. outlet
temperature (Te2)
HUMIDITY CONTROL ZONE 1
Enable compensation for room humidity, ZONE LT1
NOT = Disabled
YES = Enabled
Room relative humidity value to start increasing water temperature
set point
Maximum temperature hysteresis corresponding to 100%
relative humidity
Enable contact HL1 as DEHUMIDIFIER (The contact closes and the
dehumidifier is activated when the humidity measured by the probe
on the A5 room controller exceeds the value set for parameter 0172)
HEATING compensation curve for HEAT PUMP MODE (THE TEMPERATURES MUST DIFFER FROM THOSE IN ZONE 1 & 2 BY AT
LEAST +3°C IN HEATING AND -3°C IN COOLING)
Enable compensation curve NOT = Disabled YES = Enabled
Compensation curve number
Enable room temperature influence
NOT = Disabled
YES = Enabled
Room Authority
MINIMUM set point limit curve
MAXIMUM set point limit curve
COOLING compensation curve for HEAT PUMP MODE (THE TEMPERATURES MUST DIFFER FROM THOSE IN ZONE 1 & 2 BY AT
LEAST +3°C IN HEATING AND -3°C IN COOLING)
Enable compensation curve NOT = Disabled YES = Enabled
Maximum temperature set point limit in cooling mode (Tm1)
Minimum outside temperature corresponding to max. outlet
temperature (Te1)
Minimum temperature set point limit in cooling mode (Tm2)
Maximum outside temperature corresponding to min. outlet
temperature (Te2)
Device address setting
ZONE 1 Room control unit address setting
For systems with high temperature zone (example bathroom radiators) managed using a thermostat not supplied by Manufacturer, set the
HEATING compensation curve, parameter 0159, to a value so as to reach a suitable outlet temperature for radiators.
The mixed zone is managed according to the compensation curve set for parameter 0174.
* obligatory values for the present configuration
68
i-BX-(Y)_i-BX-N-(Y) EN
Parameter
Menu
Default
no.
Mn01
016A
NOT
Mn01
0101
Mn01
012T
0-10
Mn01
0167
NOT
Mn01
0174
0,7
Mn01
0178
NOT
Mn01
0179
30
Mn01
0180
23
Mn01
0181
45
Mn01
0169
NOT
Mn01
0132
20
Mn01
0133
23
Mn01
0134
18
Mn01
0135
36
Mn01
0171
NOT
Mn01
0172
70
Mn01
0173
15
Mn01
015A
Mn01
0152
NOT
Mn01
0159
Mn01
0163
NOT
Mn01
0164
30
Mn01
0165
30
Mn01
0166
48
Mn01
0154
NOT
Mn01
0128
20
Mn01
0129
23
Mn01
0130
18
Mn01
0131
36
addr
U I A
Write set value
UOM
YES
0
2*
°C
°C
°C
°C
°C
°C
°C
DEHUMIDIFIER
1
°C
°C
°C
°C
°C
°C
1
14
-
-
%
%
-
-
-
%
-