Connection instructions

To avoid interference problems the connection cables should be screened.
Table 6
Colour of wire
Armature
Armature
Field F1
Brown (also blue)
Field F2
Yellow (also red)
1.
Make sure that:
the field is correctly wired, in parallel or in series
S
the regulator is correctly wired for the chosen armature and speed (see
S
manual for the regulator in question).
2. The direction of rotation of the motor can be changed if necessary by switching
the polarity of the rotor
3. Various types of sensors can be connected to the motor, see Accessories.
4. See also dimension drawing on page 32.
4

OPERATION

4.1

General

General safety regulations for the handling of the equipment appear from
page 19. Read through before you start using the equipment!
WARNING!
Rotating parts can cause injury, take great care.
Set the desired speed manually using any of the regulators PEG1, PEH, PEF or PTF.
All personnel who work with the A6 VEC must be thoroughly familiar with:
the operation of the unit
S
the function of the unit
S
all relevant safety precautions.