Page 3
01. SAFETY INSTRUCTIONS ATTENTION: GENERAL WARNINGS This product is certified in accordance with European • This manual contains very important safety and usage Community (EC) safety standards. information. very important. Read all instructions carefully before beginning the installation/usage procedures and keep This product complies with Directive 2011/65/EU of the this manual in a safe place that it can be consulted whenever European Parliament and of the Council, of 8 June 2011, on...
Page 4
01. SAFETY INSTRUCTIONS 01. SAFETY INSTRUCTIONS persons without any knowledge of the product, provided that on the power supply cable. Please note that all the cables must these are supervision and instructions given by persons with enter the central from the bottom. experienced in terms of usage of the product in a safe manner •...
01. SAFETY INSTRUCTIONS 02. CONTROL BOARD CHARACTERISTICS The MC60 is a control board with built-in radio control system, developed for the consult this manual, contact a technician. automation of sliding, sectional gates, barriers or 24V electromechanical pillar. • Keep the operation area of the motorized gate free while the gate in in motion, and do not create strength to the gate movement.
02. CONTROL BOARD 02. CONTROL BOARD CONNECTORS BUTTONS AND LEDs MENU • Access the Menu CMD • Commands programmation 10 11 15 16 17 19 20 21 22 23 24 UP • Navigate through menus/values LAMP MOT1 BATT DW • Navigate through menus/values 01 •...
03. CONEXION SCHEME BARRIERS [BR] • MC60 control board (Interior of the barrier) • Módulo MP106 LGHI • MP106 module in the interior 12V+ GI RGI • LED strip LAMP MOT1 BATT (Flashing Light) • Power supply 12VDC 36 W •...
If limit switches are not used, If you want them to always Shunt the FO - FC - ↓ inputs. be connected, make a bridge (shunt) between the "↓" and LB of the MC60 control panel. LAMP MOT1 BATT LIGHT MONO TEMP.
03. CONEXION SCHEME MASTER - SLAVE The function parameters marked below must respect these values: MASTER SLAVE P7=00 or 02 P4=0 P6 LA=0 E0 PL=01 E9=0 P5 LE=0 P7=00 or 02 • NOTE The value selected in P7 must be the same in both control boards. LAMP MOT1 LAMP...
03. INSTALLATION 03. INSTALLATION BASE INSTALLATION PROCESS TRANSMITTERS Transmitter programming for total opening. Transmitter programming for pedestrian opening. The installation process assumes that the gate already has mechanical or electrical limit switches installed. For more information read the motor's manual. •...
Page 13
03. INSTALLATION 03. INSTALLATION FUNCTIONS "P" MENUS MAX. MIN. FACTORY MENU FUNCTION STATE PAGE We can only go into programming with the gate electrically stumbled. PROGRAMMABLE VALUE Automatic Programming The functions of the plant are divided into 2 areas: Manual Programming Slide gates "P"...
Page 14
03. INSTALLATION 04. PROGRAMMING "P" "E" MENUS COURSE PROGRAMMING MAX. MIN. FACTORY MENU FUNCTION STATE PAGE PROGRAMMABLE VALUE Automatic course scheduling Manual course programming System type Desactivates present man Activates present man This menu allows you to This menu allows This menu allows you to automatic engine manually program the...
Page 15
04. PROGRAMMING "P" 04. PROGRAMMING "P" DECELERATION TIME ADJUSTMENT FORCE AND SENSIBILITY ADJUSTMENT 01 • Use UP until appears This menu allows to set the deceleration time at opening and closing. 02 • Press MENU will appear 03 • Press MENU to edit the value. 04 •...
Page 16
04. PROGRAMMING "P" 04. PROGRAMMING "P" PAUSE TIME PHOTOCELLS 2 PROGRAMMING 01 • Use UP until appears Allows to program le security behavior LA (photocell 2). 02 • Press MENU will appear . Use UP or DW to navigate the parameters. 03 •...
Page 17
04. PROGRAMMING "P" 04. PROGRAMMING "P" OPERATING LOGIC REMOTE PROGRAMMING 01 • Use UP until appears 01 • Use UP until appears 02 • Press MENU will appear 02 • Press MENU will appear 03 • Press MENU to edit the value. 03 •...
Page 18
05. PROGRAMMING "E" 05. PROGRAMMING "E" SOFT START FOLLOW ME 00 function disabled 00 off 01 function activated after opening 01 active 02 function activated on opening Enables or disables the soft start. With the soft start function activated, at each start of move- Allows you to activate the Follow me option.
05. PROGRAMMING "E" 05. PROGRAMMING "E" BRAKE/LOCK/PUSH MANUEVERS COUNTER Allows to activate the electronic brake and change the behaviour of the LK output (lock) This menu allows you to view the number of maneuvers performed. (complete maneuver means opening and closing). Resetting the control board does not clear the maneuver count.
05. PROGRAMMING "E" RESET - RESET FACTORY VALUES Only the maneuver counter will always have the data stored. 01 • Use UP until appears 02 • Press MENU will appear 03 • Press MENU to edit the value. 04 • Use UP and DW to change the value. 05 •...
07. DISPLAY DISPLAY INDICATIONS MENU DESCRIPTION MENU DESCRIPTION In the still position, fully open All commands erased In the still position, intermediate position Command triggered from the indicated position In the still position, fully closed Obstructed photocell Full opening button pressed Obstructed photocell Pedestrian opening button pressed In pause time...
Page 22
08. TROUBLESHOOTING INSTRUCTIONS FOR FINAL CONSUMERS / TECHNICIANS Anomaly Procedure Behavior Procedure II Discovering the origin of the problem • Motor doesn’t • Make sure you • Still not working. • Consult a MOTORLINE 1 • Open control box and check if 3 •...
Need help?
Do you have a question about the MC60 and is the answer not in the manual?
Questions and answers