Summary of Contents for Motorline professional MC61PL

  • Page 1 MC61PL USER/INSTALLER MANUAL MC61-PL-3.6...
  • Page 2 00. SAFETY INSTRUCTIONS 00. SAFETY INSTRUCTIONS STANDARDS TO FOLLOW STANDARDS TO FOLLOW ATTENTION: • It is important for your safety that these instructions are followed. • Keep these instructions in a safe place for future reference. • The ELECTROCELOS S.A. is not responsible for the improper use of the product, This product is certified in accordance with European Community or other use than that for which it was designed.
  • Page 3: Table Of Contents

    01. CONTENT INDEX 02. CONNECTIONS SCHEME CONNECTION OF COMPONENTES TO THE CONTROL BOARD 03. CONTROL BOARD TECHNICAL SPECIFICATIONS 04. REMOTE CONTROLS PROGRAMMING REMOTE CONTROLS ERASE REMOTE CONTROLS 05. FUNCTIONS FUNCTION’S CHART AUTOMATION SENSIBILITY PROGRAMMING OPENING AND CLOSING COURSE PROGRAMMING ENABLE/DISABLE SAFETY PHOTOCELLS PROGRAMMING AUTOMATIC CLOSING ENABLE/DISABLE CONDOMINIUM FUNCTION ENABLE/DISABLE STOP...
  • Page 4: Connections Scheme

    02. CONNECTIONS SCHEME COMPONENTS CONNECTION TO THE CONTROL BOARD The use of photocells or magnetic coil is essential to ensure the safety in the use of MC61PL automation. RGB GND + Photocell 12/24V COM NC DV 12/24V module FLH FC GND +...
  • Page 5: Control Board

    03. CONTROL BOARD 05. FUNCTIONS TECHNICAL SPECIFICATIONS FUNCTION’S BOARD The control board MC61PL has a menu that allows access to all automatic configurations. • Power supply 230Vac 50/60Hz • Battery input 24Vdc - 7AH máx. Automation sensibility programming Enable/disable condominium function...
  • Page 6: Opening And Closing Course Programming 5A

    05. FUNCTIONS 05. FUNCTIONS OPENING AND CLOSING COURSE PROGRAMMING ENABLE/DISABLE SAFETY PHOTOCELLS Note • In the course programmation, batteries should be always connected. The automatic bollard When photocells enabled, if any obstacle interrupt them (if the automatic bollard is closing), the can be positioned at any point.
  • Page 7: Programming Automatic Closing 6A

    05. FUNCTIONS 05. FUNCTIONS PROGRAMMING AUTOMATIC CLOSING ENABLE/DISABLE CONDOMINIUM FUNCTION 0-Disabled Option 0 disables the automatic closing, and the gate will close only if it receives an order from a configured device. • If you send an order to the bollard completely open, it will close. Any option between 1 and 9, multiplied by 5, sets the automatic closing time, the minimum is 5 •...
  • Page 8: Enable/Disable Stop 7A

    05. FUNCTIONS 05. FUNCTIONS ENABLE/DISABLE STOP INCREASE OR DECREASE DECELERATION • When this function is activated, the control board will only work if the bollard is closed. If the The deceleration reduce the motor speed in the final part of the course (opening or closing). Without deceleration - select the value 0 bollard is open, the control board reject any opening or closing order.
  • Page 9: Enable/Disable Follow Me

    05. FUNCTIONS ENABLE/DISABLE FOLLOW ME With the “Follow Me” function activated, whenever the photocells detect the passage of a user/ obstacle, the control board will automatically start the closing maneuver 3 seconds later. 0 - Disable | 1 - Enable 1 •...
  • Page 10: Troubleshooting

    06. TROUBLESHOOTING INSTRUCTIONS FOR FINAL CONSUMERS/TECHNICIANS Anomaly Procedure Behavior Procedure II Discovering the origin of the problem 1 • Open the control board box; 2 • Measure the 24V output of the transformer to detect the fault location; • Make sure you A) Has 24V: have 230V power 1 •...