Input Jumper Settings
The tables below show how to set a specific jumper to change input functionality. To access the I/O
jumpers, you must open the controller according to the instructions beginning on page 11.
 Incompatible jumper settings and wiring connections may seriously damage the controller.
 Do not move JP2.
Digital Inputs 0-11: Set Type
Set to
JP1 (all Inputs)
npn (sink)
A
pnp (source)*
B
Inputs 10/11: Set as Digital or Analog
Set to
JP5 (Input 10)
Digital*
A
Analog
B
Analog Inputs AN0/AN1: Set Type
Set to
JP3 (AN0)
Voltage*
A
Current
B
*Default settings
I/O Wiring
Input wiring
6
JP6 (Input 11)
A
B
JP4 (AN1)
A
B
npn (sink) Input