Unitronics Vision OPLC V130-J-T2 Installation Manual

Unitronics Vision OPLC V130-J-T2 Installation Manual

Hide thumbs Also See for Vision OPLC V130-J-T2:

Advertisement

Quick Links

Vision™ OPLC™
V130-33-T2/V130-J-T2
V350-35-T2/V350-J-T2
V430-J-T2
General Description
All of the controllers covered in this guide are micro-OPLCs, rugged programmable logic controllers that
comprise built-in operating panels and on-board I/Os.
Item
On-board I/O
Screen
Keypad
Function Keys
Com Port, Built-in
RS232/485
USB device,
mini-B
Com Ports, separate
order, user-installed
* V430J comprises both RS232/485 and USB ports; note that only one channel may be used at a time.
Standard Kit Contents
Item
Controller
Terminal Blocks
Battery (installed)
Slides
(2 sets of key labels)
Mounting Brackets
Rubber Seal
Programming cable
+ RS232 adapter
USB
programming cable
Unitronics
Installation Guide
12 Digital Inputs, including 2 Analog,
3 HSC/Shaft-encoder inputs
12 Transistor Outputs
V130-T2
V130J-T2
2.4"
Yes
None
Yes
None
The user may install a CANbus port (V100-17-CAN), and one of the following:
RS232/RS485 port (V100-17-RS4/V100-17-RS4X)
Ethernet (V100-17-ET2)
Profibus Slave (V100-17-PB1)
V130-T2
V130J-T2
None
Model Dependent
3.5" Color Touch
Yes
Yes
None
None
Yes
Yes
Yes
Yes (2 parts)
Yes
Yes
None
V350-T2
V350J-T2
None
Yes
Yes
None
V350-T2
V350J-T2
Yes
V430J-T2
4.3" Color Touch
Yes*
Yes*
V430J-T2
None
Yes (4 parts)
None
Yes
1

Advertisement

loading

Summary of Contents for Unitronics Vision OPLC V130-J-T2

  • Page 1 Standard Kit Contents V130-T2 V350-T2 V430J-T2 Item V130J-T2 V350J-T2 Controller Terminal Blocks Battery (installed) Slides None None (2 sets of key labels) Mounting Brackets Yes (2 parts) Yes (4 parts) Rubber Seal Programming cable None + RS232 adapter None programming cable Unitronics...
  • Page 2: Environmental Considerations

    All examples and diagrams are intended to aid understanding, and do not guarantee operation. Unitronics accepts no responsibility for actual use of this product based on these examples. Please dispose of this product according to local and national standards and regulations.
  • Page 3: Panel Mounting

    4. Tighten the bracket’s screws against the panel. Hold the bracket securely against the unit while tightening the screw. 5. When properly mounted, the controller is squarely situated in the panel cut-out as shown in the accompanying figures. V130/V350/V130J/V350J Unitronics...
  • Page 4 DIN-rail Mounting (V130/V350/V130J/V350J) 1. Snap the controller onto the DIN rail as shown in the figure to the right. 2. When properly mounted, the controller is squarely situated on the DIN-rail as shown in the figure to the right. Unitronics...
  • Page 5: Wiring Procedure

    - Inputs 1, 3 and 5 can function as either counter reset, as part of a shaft-encoder, or as normal digital inputs. If inputs 0, 2 and 4 are set as high-speed counters (without reset), inputs 1, 3 and 5 can function as normal digital inputs. Unitronics...
  • Page 6 Inputs 10/11: Set as Digital or Analog Set to JP5 (Input 10) JP6 (Input 11) Digital* Analog Analog Inputs AN0/AN1: Set Type Set to JP3 (AN0) JP4 (AN1) Voltage* Current *Default settings I/O Wiring npn (sink) Input Input wiring HSC input wiring Unitronics...
  • Page 7 HSC input wiring Shaft-encoder Analog Input Analog input wiring, current (2/3-wire) Analog input wiring, current (4-wire), Voltage Shields should be connected at the signal’s source. The 0V signal of the analog input must be connected to the controller’s 0V. Unitronics...
  • Page 8: Power Supply

    To maximize system performance, avoid electromagnetic interference by: Mounting the controller on a metal panel. Connect each common and ground connection directly to the earth ground of your system. For ground wiring uses the shortest and thickest possible wire. Unitronics...
  • Page 9 To do so, remove the RS485 connector (pins 1 & 6) from the PLC and connect a standard RS232 programming cable. Note that this is possible only if DTR and DSR signals of RS232 are not used (which is the standard case). Unitronics...
  • Page 10 ** Causes the unit to function as an end unit in an RS485 network USB Port The USB port is not isolated. Caution Make sure that the PC and the controller are grounded to same potential. The USB port may be used for programming, OS download, and PC access. Unitronics...
  • Page 11 Vision™ OPLC™ Opening the Controller Before performing these actions, touch a grounded object to discharge any electrostatic charge. Avoid touching the PCB board directly. Hold the PCB board by its connectors. 1. Turn off the power supply, disconnect, and dismount the controller. 2.