Download Print this page
Unitronics Vision V130-J-TR34 User Manual
Unitronics Vision V130-J-TR34 User Manual

Unitronics Vision V130-J-TR34 User Manual

Hide thumbs Also See for Vision V130-J-TR34:

Advertisement

Quick Links

Vision™PLC+HMI
V130-33-TR34/V130-J-TR34
V350-35-TR34/V350-J-TR34
V430-J-TR34
V130-33-R34/V130-J-R34
V350-35-R34/V350-J-R34
V430-J-R34
General Description
The products listed above are micro-PLC+HMIs, rugged programmable logic controllers that comprise
built-in operating panels.
Detailed Installation Guides containing the I/O wiring diagrams for these models, technical specifications,
and additional documentation are located in the Technical Library in the Unitronics website:
https://unitronicsplc.com/support-technical-library/
Item
On-board I/O
Screen
Keypad
Function Keys
Com Port, Built-in
RS232/485
USB device, mini-B
Com Ports, separate
order, user-installed
* V430J/V350/V350J comprises both RS232/485 and USB ports; note that only one channel may be
used at a time.
Standard Kit Contents
Item
Controller
Terminal Blocks
Battery (installed)
Mounting Brackets
Rubber Seal
Unitronics
User Guide
22 Digital Inputs, including 3 HSC/Shaft-encoder Inputs,
2 Analog inputs
8 Relay Outputs
22 Digital Inputs, including 3 HSC/Shaft-encoder Inputs,
2 Analog Inputs
12 Relay Outputs
V130-TR34
V130-R34
V130J-TR34
V130J-R34
2.4"
Yes
None
Yes
Yes
None
None
The user may install a CANbus port (V100-17-CAN), and one of the following:
RS232/RS485 port (V100-17-RS4/V100-17-RS4X)
Ethernet (V100-17-ET2)
Profibus Slave (V100-17-PB1)
V130-TR34
V130-R34
V130J-TR34
V130J-R34
4 high-speed npn Transistor Outputs
V350-TR34
V350J-TR34
Model Dependent
3.5" Color Touch
Yes*
V350-TR34
V350J-TR34
Yes
Yes
Yes
Yes (2 parts)
Yes
V350-R34
V430J-TR34
V350J-R34
V430J-R34
4.3" Color
Touch
None
Yes
Yes*
Yes*
Yes*
V350-R34
V430J-TR34
V350J-R34
V430J-R34
Yes (4 parts)
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the Vision V130-J-TR34 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Unitronics Vision V130-J-TR34

  • Page 1 The products listed above are micro-PLC+HMIs, rugged programmable logic controllers that comprise built-in operating panels. Detailed Installation Guides containing the I/O wiring diagrams for these models, technical specifications, and additional documentation are located in the Technical Library in the Unitronics website: https://unitronicsplc.com/support-technical-library/ V130-TR34...
  • Page 2 ▪ All examples and diagrams are intended to aid understanding, and do not guarantee operation. Unitronics accepts no responsibility for actual use of this product based on these examples. ▪ Please dispose of this product according to local and national standards and regulations.
  • Page 3 4. Tighten the bracket’s screws against the panel. Hold the bracket securely against the unit while tightening the screw. 5. When properly mounted, the controller is squarely situated in the panel cut-out as shown in the accompanying figures. V130/V350/V130J/V350J Unitronics...
  • Page 4 DIN-rail as shown in the figure to the right. UL Compliance The following section is relevant to Unitronics’ products that are listed with the UL. The following models: V130-33-R34, V130-J-R34, V130-T4-ZK1, V350-35-RA22, V350-J-RA22, V350-35-R34, V350-J-R34, V430-J-R34 are UL listed for Hazardous Locations.
  • Page 5 Class I, Division 2, Groups A, B, C and D These Release Notes relate to all Unitronics products that bear the UL symbols used to mark products that have been approved for use in hazardous locations, Class I, Division 2, Groups A, B, C and D.
  • Page 6 à risques, Class I, Division 2, Groups A, B, C et D. Cette note fait référence à tous les produits Unitronics portant le symbole UL - produits qui ont été certifiés pour une utilisation dans des endroits dangereux, Classe I, Division 2, Groupes A, B, C et D.
  • Page 7 Inputs 1, 3, and 5 can function as either counter reset, as part of a shaft-encoder, or as normal digital inputs. If inputs 0, 2 and 4 are set as high-speed counters (without reset), inputs 1, 3 and 5 can function as normal digital inputs. Unitronics...
  • Page 8 Inputs 14/15: Set as Digital or Analog Set to JP1 (Input 14) JP2 (Input 15) Digital* Analog Analog Inputs AN0/AN1: Set Type Set to JP5 (AN0) JP4 (AN1) Voltage Current* *Default settings I/O Wiring npn (sink) Input Wiring Input wiring HSC input wiring Unitronics...
  • Page 9 Vision™PLC+HMI pnp (source) Input Wiring Input wiring HSC input wiring Shaft-encoder Analog Input Wiring Analog input wiring, current (2 wire) Analog input wiring, current (3-wire) Unitronics...
  • Page 10 Analog input wiring, current (4-wire) Analog input wiring, voltage Shields should be connected at the signal’s source. ▪ The 0V signal of the analog input must be connected to the controller’s 0V. ▪ npn Outputs TR34 Relay Outputs TR34 Unitronics...
  • Page 11 These models comprise a built-in RS232/RS485 serial port (Port 1) ▪ V430J/V350/V350J These models comprise built-in ports: 1 USB and 1 RS232/RS485 (Port 1). Note that physically connecting a PC to the controller via USB suspends RS232/RS485 communications via Port 1. When the PC is disconnected, RS232/RS485 resumes. Unitronics...
  • Page 12 To do so, remove the RS485 connector (pins 1 & 6) from the PLC and connect a standard RS232 programming cable. Note that this is possible only if DTR and DSR signals of RS232 are not used (which is the standard case). Unitronics...
  • Page 13 ** Causes the unit to function as an end unit in an RS485 network USB Port ▪ The USB port is not isolated. Caution Make sure that the PC and the controller are grounded to same potential. The USB port may be used for programming, OS download, and PC access. Unitronics...
  • Page 14 1. Gently replace the board. Make certain that the pins fit correctly into their matching receptacle. Do not force the board into place; doing so may damage the controller. 2. Replace the back cover of the controller and fasten the corner screws. Unitronics...
  • Page 15 10ms typical, when used as normal digital input Input Cable length Normal digital Input Up to 100 meters High Speed Input Up to 50 meters, shielded, see Frequency table below High speed inputs Specifications below apply when wired as HSC/shaft-encoder. See Note 2. Unitronics...
  • Page 16 0.9% Yes – if an analog input deviates above the permissible range, Status indication its value will be 1024. Notes: 4. For example, if 2 inputs are configured as analog, it takes 2 scans to update all analog values. Unitronics...
  • Page 17 Screen brightness control Via software Via software (Store value to SI 9, (Store value to SI 9, values range: 0 to 100%) 0 = Off, 1 = On) Virtual Keypad None Displays virtual keyboard when the application requires data entry. Unitronics...
  • Page 18 Removable Memory Micro SD card Compatible with standard SD and SDHC; up to 32GB store datalogs, Alarms, Trends, Data Tables, backup Ladder, HMI, and OS. See Note 7 Notes: 7.User must format via Unitronics SD tools utility. Unitronics...
  • Page 19 - An additional port (Port 2). Available port types: RS232/RS485 isolated/non-isolated, Ethernet - A CANbus port Port module documentation is available on the Unitronics website. 10. Note that physically connecting a PC to the controller via USB suspends RS232/RS485 communications via Port 1.
  • Page 20 Relative Humidity (RH) 10% to 95% (non-condensing) Mounting method Panel mounted (IP65/66/NEMA4X) DIN-rail mounted (IP20/NEMA1) Operating Altitude 2000m (6562 ft) Shock IEC 60068-2-27, 15G, 11ms duration Vibration IEC 60068-2-6, 5Hz to 8.4Hz, 3.5mm constant amplitude, 8.4Hz to 150Hz, 1G acceleration. Unitronics...
  • Page 21 0-5 VDC for Logic ‘1’ Input Current 3.7mA@24VDC 6.5KΩ Input impedance Response Time 10ms typical, when used as normal digital input Input Cable length Normal digital Input Up to 100 meters High Speed Input Up to 50 meters, shielded, see Frequency table below Unitronics...
  • Page 22 0.9% Yes – if an analog input deviates above the permissible range, its value will be Status indication 1024. Notes: 4. For example, if 2 inputs are configured as analog, it takes 2 scans to update all analog values. Unitronics...
  • Page 23 Refer to V130 the keys. Refer to V350 Keypad Slides.pdf. Keypad Slides.pdf. A complete set of blank Two sets of slides are slides is available by supplied with the separate order controller: one set of arrow keys, and one blank set. Unitronics...
  • Page 24 Removable Memory Micro SD card Compatible with standard SD and SDHC; up to 32GB store datalogs, Alarms, Trends, Data Tables, backup Ladder, HMI, and OS. See Note 6 Notes: 6. User must format via Unitronics SD tools utility. Unitronics...
  • Page 25 - An additional port (Port 2). Available port types: RS232/RS485 isolated/non-isolated, Ethernet - A CANbus port Port module documentation is available on the Unitronics website. 9. Note that physically connecting a PC to the controller via USB suspends RS232/RS485 communications via Port 1.
  • Page 26 8.4Hz to 150Hz, 1G acceleration. The information in this document reflects products at the date of printing. Unitronics reserves the right, subject to all applicable laws, at any time, at its sole discretion, and without notice, to discontinue or change the features, designs, materials and other specifications of its products, and to either permanently or temporarily withdraw any of the forgoing from the market.