Silence Feature - Ei Electronics BROOKS EIB160e Series Instruction Manual

230v- smoke & heat alarms
Table of Contents

Advertisement

WARNING: Electrical shock hazard. Disconnect the AC
mains at the fuse box or circuit breaker powering the
Alarm before following the cleaning instructions.
Clean your Alarm regularly, particularly in dusty areas.
Use the narrow nozzle attachment of your vacuum
cleaner to remove dust, insects and cobwebs from the
sides and cover slots where the smoke or heat enters.
To clean the cover, wipe with a damp cloth. Dry cover
thoroughly with a lint free cloth.
WARNING: Do not paint your Alarm.
Other than the cleaning described above, no other
customer servicing of this product is required. Repairs,
when needed, must be performed by the manufacturer.
All Alarms are prone to dust and insect ingress which
can cause nuisance/false alarms or failure to alarm.
In certain circumstances even with regular cleaning,
contamination can build up in the smoke sensing
chamber causing the Alarm to sound or fail. If this
happens the Alarm must be returned to the manufacturer
for servicing or replacement. Contamination is beyond
our control, it is totally unpredictable and is considered
normal wear and tear.
For this reason, contamination is not covered by the
guarantee and a charge is made for servicing such units.
If you experience persistent nuisance/false alarms it may
mean that the environment may not be suitable for your
particular Alarm type.
Nuisance / False Alarms
When sure that it is just a nuisance/false alarm, simply
press the test/silence button briefly on the Alarm to
silence the unit for 10 minutes.
If, when the Alarm sounds, there is no sign of smoke,
heat or noise to indicate that there is a fire, you should
get your family into a safe place, before you start
investigating.
Check the house carefully in case there is a small fire
smouldering somewhere.
Check whether there is some source of smoke or fumes,
for example cooking fumes being drawn past the Smoke
Alarm by an extractor.
If there are frequent nuisance/false alarms it may be
necessary to re-locate the device away from the source
of the fumes or replace an Ionisation Alarm with an
Optical Alarm. If for some reason the Alarm continues
to sound without smoke or heat being present (due to
insect infestation or contamination build-up for example)
the units can be silenced by disconnecting the mains
power and removing the unit - see "ALARM REMOVAL"
section - page 10 (Installer)
If cleaning the Alarm does not correct the problem
it can be returned to the manufacturer for repair or
replacement - see "Service and Guarantee" section.
All the Smoke Alarms have a combined Test/Silence
Button to help you control nuisance/false alarms.
1. To silence a nuisance/false alarm, press the Test/
Silence Button located on the cover. The Alarm will
automatically switch to a reduced sensitivity condition
for a 10 minute period (very large levels of smoke
from a nearby fire will override the silence period).
Cleaning

Silence Feature

4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Brooks eib161eBrooks eib164eBrooks eib166eBrooks eib166e dhhs

Table of Contents