10277-R12-9V-UC
29/9/09
IMPORTANT NOTICE
WHEN THE BATTERY IS
FIRST CONNECTED THE
ALARM MAY SOUND FOR
2-3 SECONDS.
THIS IS NORMAL.
IT MEANS THE BA TTERY IS
CONNECTED CORRECTLY.
© Ei Electronics 2008

SMOKE ALARM

9 VOLT IONISATION
Ei100B
Standard Alarm
Ei100L
Emergency Light
INSTRUCTION LEAFLET (for all Models)
Contains vital information on unit operation and installation.
Read and retain carefully. If you are just installing this unit this
leaflet MUST be given to the householder.
7:49 AM
Page 1
Models
Ei100S
Silencer
Ei100C
Interconnect
1
P/N B10277 Rev 12

Advertisement

Table of Contents
loading

Summary of Contents for Ei Electronics Ei100B

  • Page 1: Smoke Alarm

    WHEN THE BATTERY IS FIRST CONNECTED THE ALARM MAY SOUND FOR 2-3 SECONDS. THIS IS NORMAL. IT MEANS THE BA TTERY IS CONNECTED CORRECTLY. © Ei Electronics 2008 P/N B10277 Rev 12 SMOKE ALARM 9 VOLT IONISATION Models Ei100B Ei100S...
  • Page 2 10277-R12-9V-UC 29/9/09 7:49 AM Page 2 Basic information about your Smoke Alarm A Smoke Alarm is an early warning device. Used correctly it can give you and your family valuable extra time to escape. Note:- • When the battery is first connected the Alarm may sound for 2-3 seconds - this is normal.
  • Page 3 10277-R12-9V-UC 29/9/09 7:49 AM Page 3 Bedroom Kitchen Dining Bedroom Bedroom Figure 1: Single storey Dwelling Bedroom Dining Kitchen Recreation Living Bedroom Bedroom Figure 2: Single storey Dwelling with separate sleeping areas Figure 3: Two Storey Dwelling Recommended protection, Figure 1,2, & 3 Minimum protection •...
  • Page 4: Positioning Your Smoke Alarm

    10277-R12-9V-UC 29/9/09 7:49 AM Page 4 a fire on lower floors in sufficient time to ensure an adequate escape. (c) Maximum Protection. For maximum protection you should put individual Smoke Alarms in all the rooms where fire is most likely to break out (apart from the locations to avoid, mentioned on page 5).
  • Page 5 10277-R12-9V-UC 29/9/09 7:49 AM Page 5 (b) Wall Mounting. When a ceiling position is not practical (for example on a ceiling having exposed beams or joists, or built-in radiant heating) put the top edge of your Smoke Alarm between 15 and 30 cm (6 and 12 inches) below the ceiling.
  • Page 6 10277-R12-9V-UC 29/9/09 7:49 AM Page 6 Installing your Smoke Alarm (a) Attaching to Ceiling or Wall. (NB: for wiring the Ei100C Interconnect model see page 9) The Smoke Alarm is battery operated and needs no wiring, (Ei100C excepted). Use figure 6 below, as a help in mounting.
  • Page 7 10277-R12-9V-UC 29/9/09 7:49 AM Page 7 Figure 7 9 Volt Battery Battery Connectors NOTE: You may hear a loud chirp when attaching the Battery Connectors to the Battery. N.B. The emergency light Smoke Alarm needs 2 batteries (see page 9 for details). Test the installed Smoke Alarm - see section 5(a) below.
  • Page 8 10277-R12-9V-UC 29/9/09 7:49 AM Page 8 This can set fire to the Alarm and damage the house. We do not recommend testing with smoke or heat as the results can be misleading unless special apparatus is used. (b) Replacing the Battery(ies) Test the alarm for correct operation using the test button whenever the battery(ies) is/are replaced.
  • Page 9 10277-R12-9V-UC 29/9/09 7:49 AM Page 9 batteries, an alkaline battery and a general purpose battery. 1. Connect an alkaline battery (use only Duracell MN1604 or Eveready 522) to the blue battery connector to power the light. This battery when fresh will normally last 1 year in the stand by mode and provide over 15 minutes of light when in alarm.
  • Page 10: Important Safeguards

    10277-R12-9V-UC 29/9/09 7:49 AM Page 10 Figure 10 WIRING HOLE TEST BUTTON CONTACTS INTERCONNECT WIRES TERMINAL 1 TERMINAL 2 (d) Silencer Smoke Alarm Ei100S This model has a special false alarm silencer feature to help you control nuisance false alarms. 1.
  • Page 11 10277-R12-9V-UC 29/9/09 7:49 AM Page 11 • Do not disconnect battery to stop alarm sounding. (Fanning vigorously with a newspaper or similar will remove nuisance smoke from the Smoke Alarm and stop it sounding.) • Do not attempt to recharge or burn batteries, as they may explode.
  • Page 12 10277-R12-9V-UC 29/9/09 7:49 AM Page 12 with: fires caused by smoking in bed, escaping gas, violent explosions. poor storage of flammable rags and/or liquids, (for example petrol, paint, spirits etc), overloaded electrical circuits, arson, children playing with matches. • Smoke Alarms don’t last indefinitely. The manufacturer recommends replacement after 10 years as a precaution.
  • Page 13: Smoke Alarm - Optical Or Ionisation

    Publication entitled “Smoke Detectors in the Home” (FB2) or from your local fire prevention officer. Smoke Alarm - Optical or Ionisation? Both types respond in all standard fires but each type may respond faster to particular fires as shown. Ei Electronics manufactures Optical Smoke...
  • Page 14: Getting Your Smoke Alarm Serviced

    Alarm was purchased and the date of purchase. Five Year Product Guarantee (excluding battery) Ei Electronics guarantees this product (excluding battery) against any defects that are due to faulty material or workmanship for a five year period after the original date of consumer purchase or receipt as a gift.