Operation Section
Starting the Engine
NOTICE
Do not engage the starting motor when flywheel is
turning. Do not start the engine under load.
If the engine fails to start within 30 seconds, release
the starter switch or button and wait two minutes to
allow the starting motor to cool before attempting to
start the engine again.
4. Allow the keyswitch to return to the RUN position
after the engine starts.
5. Repeat step 2 through step 4 if the engine fails to
start.
Note: The engine should not be "raced" to speed up
the warm-up process.
6. Allow the engine to idle for 3 to 5 minutes, or allow
the engine to idle until the water temperature
indicator begins to rise. When idling after the
engine has started in cold weather, increase the
engine rpm from 1000 to 1200 rpm. This operation
will warm up the engine more quickly. Maintaining
an elevated low idle speed for extended periods
will be easier with the installation of a hand
throttle.
7. Operate the engine at low load until all systems
reach operating temperature. Check the gauges
during the warm-up period.
8. Constant speed engines could be allowed to reach
operating speed with no load. Operate the engine
for 2 minutes before applying load.
Starting the Engine
Do not use aerosol types of starting aids such as
ether. Such use could result in an explosion and
personal injury.
Note: Do not adjust the engine speed control during
start-up. The electronic control module (ECM) will
control the engine speed during start-up.
Starting the Engine
1. Disengage any equipment that is driven by the
engine.
Note: During key ON, the indicator lamps will be
illuminated for 0.5 of a second to check the lamp
operation. If any of the indicator lamps do not
illuminate check the bulb. If any indicator lamps stay
illuminated or flash, refer to Troubleshooting,
"Indicator Lamp Circuit - Test".
2. Turn the keyswitch to the RUN position. Leave the
keyswitch in the RUN position until the warning
light for the glow plugs is extinguished.
3. When the wait to start lamp for the glow plugs has
been extinguished turn the keyswitch to the
START position. The starter motor will then crank
the engine.
Note: The operating period of the wait to start lamp
for the glow plugs will change due to the ambient air
temperature.
Do not engage the starting motor when flywheel is
turning. Do not start the engine under load.
If the engine fails to start within 30 seconds, release
the starter switch or button and wait two minutes to
allow the starting motor to cool before attempting to
start the engine again.
4. Allow the keyswitch to return to the RUN position
after the engine starts.
5. Repeat step 2 through step 4 if the engine fails to
start.
i07907097