M0094137-02
For maintenance procedures refer to this Operation
and Maintenance Manual.
Aftertreatment
No special procedures are required. The exhaust
outlet of the aftertreatment should be capped. Before
storing, the engine and the aftertreatment must be
enclosed in a cover that will provide protection from
the environment. Store the engine and aftertreatment
together, the aftertreatment is matched to the engine
and not interchangeable. If the aftertreatment is
disconnected from the engine, the inlet and outlet
must be capped on the aftertreatment and engine.
Monthly Checks
The crankshaft must be rotated to change the spring
loading on the valve train. Rotate the crankshaft
more than 180 degrees. Visibly check for damage or
corrosion to the engine and aftertreatment.
Ensure that the engine and aftertreatment are
covered completely before storage. Log the
procedure in the record for the engine.
Removal from Storage
1. Install the drive belt, refer to this Operation and
Maintenance Manual, "Alternator and Fan Belts -
Inspect/Adjust" for the tension of the belt.
2. Ensure that the engine oil level is correct. Ensure
that the coolant level is correct. Ensure that the
fuel system is full and the fuel system is primed.
Refer to the Operation and Maintenance Manual,
"Fuel system - Prime" for more information.
3. Turn the power ON and check the operation of the
warning lamps. Start engine, refer to Operation
and Maintenance Manual, "Starting the Engine" for
more information.