Secutron MR-2300 Series User Manual

Secutron MR-2300 Series User Manual

Led fire alarm control panel
Hide thumbs Also See for MR-2300 Series:

Advertisement

Quick Links

MR-2300 Series
LED Fire Alarm Control Panel
User Guide
LT-953SEC Rev. 1
January 2017

Advertisement

Table of Contents
loading

Summary of Contents for Secutron MR-2300 Series

  • Page 1 MR-2300 Series LED Fire Alarm Control Panel LT-953SEC Rev. 1 User Guide January 2017...
  • Page 3: Table Of Contents

    Contents Introduction About this Manual ......................Technical Support ......................Main Display Paper labels for buttons and indicators ................The Buzzer and LED Indicators Common LED Indicators ....................3.1.1 Buzzer ..........................3.1.15 Ground Fault LED ......................3.1.16 System Reset LED ......................3.2.1 Alarm Circuit Indicators ....................
  • Page 4: Introduction

    Refer to the Glossary on page 16 for an explanation of commonly used terms in this manual. Technical Support For all technical support inquiries, please contact Secutron’s Technical Support Department between 8 A.M. and 5 P.M. (EDT) Monday through Friday, excluding holidays.
  • Page 5: Main Display

    Main Display Refer to the diagram below for the LED indicators and control buttons locations. W ALK A.C. TE S T RE MO TE CO MMO N TRO UBLE ALARM CO MMO N CP U FAIL S UP V GRO UND CO MMO N FAULT TRO UBLE...
  • Page 6: Paper Labels For Buttons And Indicators

    Main Display Paper labels for buttons and indicators Each display is supplied with laser printable labels. These labels slide into the plastic label templates on the panel.
  • Page 7: The Buzzer And Led Indicators

    The Buzzer and LED Indicators Common LED Indicators 3.1.1 Buzzer The buzzer sounds if there is a fire alarm, a supervisory alarm, or a trouble in the fire alarm system. It turns off if the condition causing the buzzer to sound goes away or if the ALM/SUP/ TBL/BLDG AUDIBLE SIL (buzzer silence) button is pressed.
  • Page 8 The Buzzer and LED Indicators 3.1.8 AUTOMATIC ALARM SIGNAL CANCEL LED (Acknowledge) If the panel is configured as a two-stage system, the AUTOMATIC ALARM SIGNAL CANCEL LED illuminates steadily when the Alarm timer is canceled by the activation of the AUTOMATIC ALARM SIGNAL CANCEL AUTOMATIC ALARM SIGNAL CANCEL or SIGNAL SILENCE buttons.
  • Page 9: Ground Fault Led

    The Buzzer and LED Indicators 3.1.14 Battery Trouble LED The amber Battery Trouble LED flashes at the trouble rate when the battery is either low or disconnected. BATTERY TROUBLE 3.1.15 Ground Fault LED The amber Ground Fault LED flashes at the trouble rate when the ground fault detector detects a ground fault on any field wiring.
  • Page 10: Alarm Circuit Indicators

    The Buzzer and LED Indicators 3.2.1 Alarm Circuit Indicators This operation applies to Initiating Circuits configured as Verified Alarm, Non-Verified Alarm, Water flow Alarm, Sprinkler Alarm, or General Alarm Circuits. The following table summarizes the indications at different events: Table 1 Alarm Circuit Indicators Event Circuit Status LED...
  • Page 11: Property And Building Safety Circuit Indicators

    The Buzzer and LED Indicators 3.2.3 Property and Building Safety Circuit Indicators This operation applies to initiating circuits configured as property and building safety circuits. The following table summarizes the indications in response to different events: Table 3 Property and Building Safety Circuit Indicators Event Circuit Status LED Configuration...
  • Page 12: Signal Circuit Indicators

    The Buzzer and LED Indicators 3.2.5 Signal Circuit Indicators This operation applies to indicating circuits of any type. The Circuit Trouble Indicator flashes amber at the Trouble Rate to indicate short-circuit or open-circuit trouble, or if the circuit is Disconnected. Table 5 Signal Circuit Indicators Event...
  • Page 13: Main Display Buttons

    Main Display Buttons System Reset Button The System Reset button resets the fire alarm control panel and all circuits. SYSTEM RESET Signal Silence Button Pressing the SIGNAL SILENCE button when the panel is in alarm deactivates any silenceable SIGNAL signal devices in the fire alarm system. Non-Silenceable signal devices are unaffected. If you SILENCE press the SIGNAL SILENCE button a second time, or if there is a subsequent alarm, the signals will re-sound.
  • Page 14: Auxiliary Disconnect Button

    Main Display Buttons Auxiliary Disconnect Button Pressing the Auxiliary Disconnect button activates the auxiliary disconnect function. Pressing the DISCONNECT button again de-activates this function. Lamp Test Button Pressing and holding the Lamp Test button causes all front panel LEDs to illuminate and sounds the buzzer.
  • Page 15: Circuit (Zone) Disconnect Buttons

    Circuit (Zone) Disconnect Buttons Circuit (zone) disconnect buttons are provided for all initiating and indicating circuits on the fire alarm control panel. These buttons are located beside their respective indicating LEDs. Pressing a circuit disconnect button disconnects that circuit from the system and turns on its trouble indicator.
  • Page 16: Glossary

    Glossary Alarm Condition Occurs when devices such as detectors, pull stations, or sprinklers are activated. In a single stage system, this condition will activate all signalling devices throughout the building. In a two stage system, this condition will activate an alert signal and the General Alarm timer. Circuits Refers to an actual electrical interface and can be classified as initiating (detection), indicating (signal), or relay.
  • Page 17 Glossary Relay Circuit A circuit in a fire alarm system that connects relay devices (e.g. fan damper relays, etc). Remote Annunciator A device that visually indicates, either by LCD or LEDs, the floor or zone where the alarm originated. Single Stage System A type of fire alarm system that immediately sounds all the signals throughout the building when an alarm is detected in any part of the system.
  • Page 20 TECHNICAL SUPPORT U.S.A CANADA - Main Office © Secutron 2017 25 Interchange Way North America 4575 Witmer Industrial Estates Printed in Canada Subject to change without prior notice Tel: (905)-695-3545 Niagara Falls, NY 14305 Vaughan, ON L4K 5W3 Tel: (888) 732-8876...

This manual is also suitable for:

Mr-2300

Table of Contents