3-1-4 Muting Setting Changing Function

The setting of the muting function can be changed.
Setting of the muting function on each beam channel
Each beam channel can be set to "valid / invalid" in the muting function respectively. (Note)
All beam channel can not be all invalid.
The factory setting of this function is valid for all beam channels.
Note: If the beam channel set to invalid in the muting function is blocked, the control output (OSSD 1 / 2) becomes "OFF" and the
muting function is canceled.
There are two setting methods, "Auto" and "Manual" to set muting beam channel.
‡ Auto setting
‡ Manual setting : Each beam channel can be set to "valid / invalid" in the muting function.
Muting maximum continuous valid time setting
Maximum continuous valid time setting for muting function can be changed.
The maximum continuous valid time is 1 to 600 sec. (1 sec. unit) or no limit.
Muting sensor output operation setting (only for Ver. 2.1 of SF4C series)
Output operation of muting sensor can be selected
)DFWRU\ VHWWLQJ LV 1212 1RUPDOO\ 2SHQ ‡ 1RUPDOO\ 2SHQ
‡ NONO (Normally Open, Normally Open)
A muting sensor which is to be connected to the muting input 1
(ON with light non-received status, ON with object approaching status and ON with object contacted status)
A muting sensor which is to be connected to the muting input 2
(ON with light non-received status, ON with object approaching status and ON with object contacted status)
‡ NONC (Normally Open, Normally Close)
A muting sensor which is to be connected to the muting input 1
(ON with light non-received status, ON with object approaching status and ON with object contacted status)
A muting sensor which is to be connected to the muting input 2
(ON with light received status, ON with object non-approaching status and ON with object non-contacted status)
Muting function only for the sensing object exit
Muting function only for the sensing object exit can be set.
When setting to the muting function only for the sensing object exit, install the muting sensor only
in the dangerous zone and the installation in the safety zone is not required.
Using conditions of the muting function only for the sensing object exit is as follows.
‡ The sensing object should move to one side.
(The sensing object should move from the dangerous zone to the safety zone.)
‡ The sensing object should pass through the sensing area within 4 sec. after the muting sensor
turns OFF. (Note)
Note: Muting time only for the sensing object exit can be set between 0 (Invalid) to 4,000ms (Unit: 100ms).
© Panasonic Industrial Devices SUNX Co., Ltd. 2013 MJE-SFCHC No.0037-80V
: The beam channel which is currently blocked is set as the "valid" beam chan-
nel. When all beam channels are in light receiving condition, the setting is not
accepted. Furthermore, in the state that all beam channels are blocked, the all
beam channels become "valid" in the muting function.
ON: The muting function is valid
OFF: The muting function is invalid
,Q FDVH XVLQJ WKH PXWLQJ IXQFWLRQ RQO\ IRU WKH VHQVLQJ REMHFW H[LW DQG WKH ÀRDWLQJ EODQNLQJ
function, set by being sure listed below.
The set beam channel number of WKH ÀRDWLQJ EODQNLQJ IXQFWLRQ LV  RU  EHDP FKDQQHO
only.
,Q FDVH PDNLQJ YDOLG WKH LQYDOLG VHWWLQJ RI ERWK HQG EHDP FKDQQHOV RI WKH ÀRDWLQJ EODQN-
ing function, set invalid the muting function of both ends of beam channels in each beam
channel setting of muting function.