Exchange Of Catalyst Agent; Waste Code - Beko BEKOKAT CC-1200 Installation And Operation Manual

Catalytic converter for removing oil from compressed air, version 11 bar
Table of Contents

Advertisement

7.5

Exchange of catalyst agent

It is recommended to replace the catalyst granules in the reactor after about 20,000 hours of
continuous operation.
The replacement of the catalyst granulate can only be carried out by
BEKO TECHNOLOGIES or by authorised skilled technical personnel authorised by the
manufacturer.
The utilised catalyst agent is not subject to mandatory labelling in accordance to the Hazardous
Substances Regulation. The customary precautionary measures for handling chemicals still
apply in this case.
NOTE
Fire prevention
Adjust the fire extinguishing measures to the working environment.
Never use water in a full jet for safety reasons.
Wear a respiratory mask independent of ambient air.
7.6

Waste code

In accordance with Directive 2008/98/EC, the following waste code has been established:
Material
Used catalysts
The corresponding material safety data sheets are available on request.
V01 / 11-043
Installation and Operation Manual BEKOKAT
Waste code
Waste code 16 08
®
83 / 88

Advertisement

Table of Contents
loading

Table of Contents