Error Display - Beko BEKOKAT CC-1200 Installation And Operation Manual

Catalytic converter for removing oil from compressed air, version 11 bar
Table of Contents

Advertisement

Installation and Operation Manual BEKOKAT
6.7

Error display

Malfunction image
The display A1 shows "Err".
Close valves V1 / V2.
The compressed air supply is interrupted.
As soon as the valves close, the potential-free alarm contact is activated, signalling the fault
by means of an external display (warning signal, indicator light, etc.). This connection option
should be used.
Cause
Error in the temperature sensor
Capillary break in the thermostat
NOTE
Skilled technical personnel
All function tests, operation, installation, configuration and maintenance of the
device must be carried out by authorised skilled personnel.
74 / 88
®
Measure
Check temperature sensor.
Replace temperature sensor if necessary.
Please contact the BEKO TECHNOLOGIES
service.
Check thermostat.
Replace temperature sensor if necessary.
Please contact the BEKO TECHNOLOGIES
service.