Reactor Temperature> + 200 °C - Beko BEKOKAT CC-1200 Installation And Operation Manual

Catalytic converter for removing oil from compressed air, version 11 bar
Table of Contents

Advertisement

6.2
Reactor temperature> + 200 °C
Malfunction image
The reactor temperature rises during operation above T> + 200 °C.
Close valves V1 / V2. The compressed air supply is interrupted.
As soon as the valves close, the potential-free alarm contact is activated, signalling the fault
by means of an external display (warning signal, indicator light, etc.). This connection option
should be used.
Cause
The system must be shut down and checked in all cases if the reactor temperature is
exceeded.
The air flow through the reactor was
interrupted for a long time.
The amount of oil entering the BEKOKAT
is too large.
In addition to the automatic closing of the valves at the inlet and outlet, in this case the manual
shut - off valves must also be closed before and after the system.
DANGER
Commissioning
Commissioning of the BEKOKAT
approval by authorised skilled technical personnel.
V01 / 11-043
Installation and Operation Manual BEKOKAT
Measure
Check
that
the
supplies compressed air to the reactor.
Establish compressed air supply.
®
Check oil separator of compressor.
®
is only permitted after inspection and
compressor
regularly
69 / 88
®