Function description of the catalytic converter

The BEKOKAT
®
catalytic converter has been developed for the treatment of oily compressed
air.
®
The BEKOKAT
catalytic converter can be installed and operated behind compressors of any
type (reciprocating compressors, screw compressors, etc.) provided the maximum operating
conditions specified are observed.
In terms of high energy efficiency, heat exchanger systems are used, which allow a return of
the exiting thermal energy into the system.
The proportion of externally supplied energy decreases accordingly after the heating phase.
B1:
Catalytic converter reactor (2)
E1:
Heating system (4)
KM:
Catalyst agent
V1:
Valve -Entry (7)
V2:
Valve - Condensate drain (oil and grease-free) (8)
W1:
Heat exchanger plate (1)
X4:
Safety valve (9)