Beko BEKOKAT CC-1200 Installation And Operation Manual page 50

Catalytic converter for removing oil from compressed air, version 11 bar
Table of Contents

Advertisement

Installation and Operation Manual BEKOKAT
DANGER
Operation without earth connection
If there is a missing earth connection (protective earth), there is a danger
that mains voltage components might become energised in case of
errors. These will pose a risk of serious or even fatal injury.
Earth connection takes place in this assembly unit via the mains
supply line.
DANGER
Operation without circuit breaker
All components that are dangerous when touched due to their voltage
must be disconnectable by means of dedicated external circuit breakers.
50 / 88
The assembly unit must always therefore be earthed and/or
connected to a protective conductor.
The assembly unit may only be connected to a grounded power
outlet.
Do not use plug adapters at the power plug. If required, have the
power plug replaced by a qualified electrician.
Only replace a damaged mains power cable with an equivalent cable.
The circuit breaker must be located in the vicinity of the system.
The circuit breaker must conform to IEC 60947-1 and IEC 60947-3.
The circuit breaker must disconnect all electrical conductors from the
mains power supply.
The circuit breaker must not be installed in the power supply line.
The circuit breaker must at all times be easily accessible to operating
personnel.
®
V01 / 11-043

Advertisement

Table of Contents
loading

Table of Contents