Fundamental Requirements For The Installation - Beko BEKOKAT CC-1200 Installation And Operation Manual

Catalytic converter for removing oil from compressed air, version 11 bar
Table of Contents

Advertisement

4.2

Fundamental requirements for the installation

1.
Set up the converter so that the system is easily accessible from the sides and from the
top.
2.
Ensure a suitable base (sufficiently stable and level) during the setting up process.
3.
The blow-off direction of the safety valve must be away from traffic routes.
®
4.
The BEKOKAT
caustic, toxic, flammable and oxidising components.
5.
When installing the BEKOKAT
liquid water or condensate gets into the BEKOKAT
6.
Please note that for longer distances between the compressor / compressed air
container and BEKOKAT
condensate.
7.
Liquid water can impair the function of the BEKOKAT
system for water and condensate discharge.
8.
We recommend the use of our CLEARPOINT
filters.
9.
Minimum ambient temperature +5 °C.
10.
Maximum ambient temperature + 45 °C.
11.
Always ensure unimpeded air exchange and sufficient ventilation.
12.
According to DIN EN 50156-1, the installation of an
EMERGENCY STOP switch / EMERGENCY STOP device is required.
NOTE
Manual shut-off valves and non-return valve
 A manual shut-off valve must be installed before and after the
 We recommend to install a BEKOKAT
 Furthermore, we strongly recommend that the BEKOKAT
V01 / 11-043
may only be operated in an environment free of aggressive, corrosive,
®
after a compressor with aftercooler, make sure that no
®
, post-condensation may occur in the pipes resulting in free
®
BEKOKAT
.
reverse flow.
equipped with a lockable bypass pipe.
Installation and Operation Manual BEKOKAT
®
.
®
. In this situation install a suitable
®
water separators and CLEARPOINT
®
check valve to safely prevent
®
®
®
is
43 / 88