Input / Output signal
1. Input signal
The level of the trigger signal input to the camera is as follows.
(1) Input from CameraLink cable
LVDS level
(2) Input from DCIN/SYNC connector
High level
: +5.0 ± 0.3V
Low level
: 0 ± 0.3 V
2. Output signal
The level of the VD and FLASH output from the camera is as follows.
High level
: +5.0Vp-p ± 0.3V
Low level
: 0.0V