Indicator Signal - Heartway Medical Products S19F User Manual

Auto folding scooter
Table of Contents

Advertisement

INDICATOR SIGNAL

The Indicator Signal Chart
Condition
Power On
(Power on by plugging in AC source and
without battery)
Flashing in three times then ON
Constant Current Mode
Constant Current Mode
Battery Fully Charged
(Terminate Current ≤ 300 ± 100mA)
Pre-Charged Mode
Pre-Charged Mode Fail
Over Voltage, Over Current, CC CV
Mode Current Fail
Mechanical Specification:
1.
Dimension: 167*74*37 mm.
2.
Weight: 410g approx.
3.
Charger output: 3‐pin connector. (Pin 1‐ Positive ; Pin 2‐ Negative ; Pin 3‐
Negative )
4.
AC socket: Standard 2‐p oblong.
5.
AC cable: National wall plug type upon request.
Operation procedures:
1.
Attention! Connect charger first to AC power *before* connecting the battery to
the charger. Plug into AC mains the "power on" indicator will be on and the
"Status" indicator will be GREEN, then connecting the battery pack to charger.
2.
If short circuit at output is found, the "Status" indicator will flash between RED
(16ms) and GREEN (496ms).The flash will be there until the system is reset
and the short part is removed.
3.
During charging, the "Status" indicator turns on RED. When full, it turns on
GREEN.
4.
To avoid the case of failed battery pack, when the charger stays in pre‐charge
stage longer than 5 hours, it will stop charging and the "Status" indicator will be
pulsed with a one second to indicate pre‐charge error.
Indicator
Slow Flash
Red and Green LEDs Quickly Flash
LED 1
OFF
ON
ON
ON
Red and Green LEDs
Flash synchronous
alternately
13
LED 2
ON
OFF
OFF
ON
OFF

Hide quick links: