Vivotek 9189 Series User Manual page 377

Fixed dome network camera
Table of Contents

Advertisement

© 2019 VIVOTEK INC. All Right Reserved
8.16 Send Data
Note: This request requires Viewer privileges.
Method: GET/POST
Syntax:
http://<servername>/cgi-bin/viewer/senddata.cgi?
[com=<value>][&data=<value>][&flush=<value>] [&wait=<value>] [&read=<value>]
PARAMETER
VALUE
com
1 ~ <max. com port
number>
data
<hex decimal
data>[,<hex decimal
data>]
flush
yes,no
wait
1 ~ 65535
read
1 ~ 128
Return:
HTTP/1.0 200 OK\r\n
Content-Type: text/plain\r\n
Content-Length: <system information length>\r\n
\r\n
<hex decimal data>\r\n
Where hexadecimal data is digits from 0 ~ 9, A ~ F.
(capability_nuart > 0)
DESCRIPTION
The target COM/RS485 port number.
The <hex decimal data> is a series of digits from 0 ~ 9, A ~
F. Each comma separates the commands by 200
milliseconds.
yes: Receive data buffer of the COM port will be cleared
before read.
no: Do not clear the receive data buffer.
Wait time in milliseconds before read data.
The data length in bytes to read. The read data will be in
the return page.
VIVOTEK
235
User's Manual - 377

Advertisement

Table of Contents
loading