Vivotek 9189 Series User Manual page 312

Fixed dome network camera
Table of Contents

Advertisement

VIVOTEK
© 2019 VIVOTEK INC. All Right Reserved
NAME
exposure_manualmod
e_affect
312 - User's Manual
VALUE
SECURITY
(get/set)
-,
0/7
exposurewin.mode
.blc:hidden:,
defog:disabled:,
wdrpro:disabled:,
exposurelevel:hidd
en:,
or others
<x>: nonnegative
integer
DESCRIPTION
value.
- (ranged) : UI is fixed to multiple
selections or values.
- (enabled) : UI is checked.
- (notsupport) : the affected function
is not available.
"Affect API name" can be described in
hierarchy, such as
"exposurewin.mode.blc:disabled:"
which means blc exposure window is
disabled. API name can be one word
as well, such as
"exposurelevel:fixed:6" which means
exposurelevel is fixed to level 6.
"Description" can be a nonnegative
integer or string or NULL.
"-" means no feature is affected.
* Only available when qualitypriority
is listed in
"capability_image_c<0~(n-1)>_
exposure_modetype" and
"capability_image_c<0~(n-1)>_
exposure_mode" is 1.
* We support this parameter when
the version number (httpversion) is
equal or greater than 0305a.
When exposure manual mode is
enabled, some features may become
malfunction or be forced to a given
value. The affected functions are list
here.
The format is "Affect API
name":"Policy":"Description"
"Policy" can be categorized into
following groups:
- (disabled) : UI turns grey and users
170