Zanussi LIBERO IWOKEC-1P/1ZT Service Manual page 65

Wok induction
Table of Contents

Advertisement

LIBERO LINE WOK INDUCTION
E701
POW
Tesla
: Yes
E702
E711
POW
Yes
E712
E821
U.I
Yes
E822
E831
U.I
Yes
E832
E911
U.I
E921
U.I
E931
U.I
E941
U.I
E981
U.I
E991
U.I
E9A1
U.I
E9b1
U.I
E9C1
U.I
NOTE !
If the filters start to get dirty and limit the fresh air passage, before emitting an "over heating alarm
E421" the appliance will start to limit the energy emission of the POW, a typical call from a customer
could be " the appliance is not performing any more" or " after some time the appliance is not per-
forming".
4.9
SOFTWARE UPDATE & WIFI
The software update is not possible on the electronic boards. WIFI is not implemented at this moment.
Alarm name
Yes
Tesla:
BOARD_FAN_ER-
ROR
Yes
EXTER-
NAL_FAN_ALARM
Yes
POW_COMM_WD
OG_ALM
Yes
MACS_ACK_TOUT
BUTTON _LOW
_REF
BUTTON _LOW
_SIGNAL
BUTTON _HIGH
_REF
BUTTON _HIGH
_SIGNAL
BUTTON_ERROR -
Init
BUTTON_ERROR
– Run time
BUTTON_ERROR
– FMEA Library
BUTTON_ERROR
– FMEA short
BUTTON_ERROR
– FMEA open
Alarm description
Tesla POW: IGBT cooling fan blocked or not connected. Re-
marks:
• The alarm is reset when the U.I. stay at least 120sec of
OFF or COOLING_DOWN state, no matter if problem is
solved or not.
• About 20 sec before the alarm occurs POW sent pot fail
state to the U.I.
Foucault HC: One or more internal cooling fan blocked/not
connected/not following. Power disable depend on number of
fans blocked
Tesla POW only: External tangential fan blocked or not con-
nected.
Remarks: The alarm is reset when the U.I. stay at least
120sec of OFF or COOLING_DOWN state, no matter if prob-
lem is solved or not.
U.I1 detects POW1/POW2 communication timeout.
The alarm is showed on left display only (Both 821 and 822).
NOTE: This alarm maybe generated by:
➢ A wrong MACS connection between U.I and POW
➢ A missing or wrong ID jumper on POW board.
With appliance with more than one POW (e.g. Double Zone
Fry top) it's still possible to work with one zone only when the
other one is in error.
U.I1 detects MACS acknowledgements missing to POW1.
This alarm appears if communication is lost during standard
operation. The alarm is overridden by E821 after some sec-
onds. The alarm is showed on both display.
Touch button failure
Touch button failure
Touch button failure
Touch button failure
Touch button failure
Touch button failure
Touch button failure
Touch button failure, the alarm is showed on both display.
Touch button failure, the alarm is showed on both display.
Alarm trou-
ble shoot-
ing
Check cool-
ing fan of
POW
Check cool-
ing fan
Check com-
munication
cables POW
to U.I.
Check com-
munication
cables POW
to U.I.
Check U.I.
Check U.I.
Check U.I.
Check U.I.
Check U.I.
Check U.I.
Check U.I.
Check U.I.
Check U.I.
65