Zanussi LIBERO IWOKEC-1P/1ZT Service Manual page 64

Wok induction
Table of Contents

Advertisement

LIBERO LINE WOK INDUCTION
E431
POW
Yes
E432
Yes/
E441
POW
No
E442
E501
U.I
No
E601
POW
No
E611
POW
Tesla
: Yes
E612
Fou-
cault:
No
E641
POW
Yes
E651
POW
Yes
E661
POW
Yes
E6A1
POW
Yes
Alarm name
Yes
TEMP SENS
SLOPE_Z0 (Front
zone on Tesla
POW)
TEMP SENS
SLOPE_Z1 (Rear
zone on Tesla
POW)
PLATE_TEMP_SE
Yes
NSOR_Z0
(Front zone on
Tesla POW)
PLATE_TEMP_SE
NSOR_Z1
(Rear zone on Tesla
POW)
No
Yes
15V BAD
Yes
Tesla:
IGBT_TEMP_SENS
Fouc:
SENS_ERR_IGBT
Yes
RELAY GLUED
Yes
ADJACENT ADC
PIN FMEA ERROR
No
DATA_CRC_ER-
ROR
Yes
MAINS FRE-
QUENCY ERROR
Alarm description
Implemented on Tesla POW only: Slope detection alarm
(temperature not increasing, stuck,) on front or rear coil. This
diagnostic is only active when zone temperature is below
55°C. Intervention time depends on requested power:
• Level 8, 9, 10 : 2 min 30 sec
• Level 7
: 4 min 30 sec
• Level 5, 6
: 7 min
• Level 4
: 9 min 30 sec
• Level 3
: 14 min
• Level 1,2
: More than 3h
The error is self-resetting after two minutes that the U.I. is
OFF or COOLING_DOWN state.
NOTE: For Tesla POW with single zone configurations this
diagnostic help to diagnose the reversal of the sensor with the
dummy resistor (100kOhm resistance).
Tesla HC, HOB & WOK: Wrong electrical connection: A
cooking plate temperature sensor is present on BT300 or
BT400 connector. In this case the error is not self-resetting.
Tesla POW, FRYTOP: Two possibilities:
Cooking plate temperature sensor open, not connected, bad
circuit or short circuit. Bad circuit means temperature ≥ 290°C
on Tesla POW.
HOB or WOK configuration loaded in a FRYTOP appliance.
The error is self-resetting in case of sensor open or not con-
nected, not self-resetting in case of bad circuit or short circuit.
NOTE: Diagnostic is executed on both generators (Front and
Rear) within the single Tesla POW §
TEST WITH GENERATORS
The alarm is showed on both display (left and right). On Libero
Line this may happen when a wrong firmware is used for the
hardware.
15 Volt supply out of window
Tesla POW: IGBT/heat-sink sensor open or short or >130°C
(115°C for deactivation). One single error for both IGBT tem-
perature sensors within an POW.
Foucault HC: IGBT/heat-sink sensor open or short. The error
is self-resetting
APD relay glued, can't switch off power induction circuits.
Solder/assembly fault inside power board: short circuit on ad-
jacent pin of safety ADC.
NOTE: On Tesla POW, this error appears (on both genera-
tors) if a coil temperature sensor is disconnected / recon-
nected when the POW board is already powered on.
Foucault POW only: Internal power table missing.
Foucault POW software is equipped with an internal power
table to be used when the POW is connected without an UI
and power level set is established by a potentiometer (modu-
lar cooking range).
Even if not used on Libero Line, the POW software check the
presence of the internal power table at power-on
Power supply frequency detection error.
Acceptable range: 40% to 60% of the duty cycle @50Hz.
S3, SELF-DIAGNOSTIC
ON.
Alarm trou-
ble shoot-
ing
Check temp
sensors,
DUMMY
sensor has
been
swapped
position af-
ter .Part re-
placement.
Check temp
sensors,
DUMMY
sensor has
been
swapped
position af-
ter
Spare
Part
re-
placement
Check cor-
rect
U.I.
spare part
Check volt-
age
on
POW
Overheat-
ing,
Check
cleaning fil-
ters, clean-
ing of venti-
lators
fans
(dirt
accu-
mulation on
fan blades)
Check POW
Check temp
sensors
connectors
Wrong
spare part.
Check
Power sup-
ply
fre-
quency
64