Zanussi LIBERO IWOKEC-1P/1ZT Service Manual page 33

Wok induction
Table of Contents

Advertisement

LIBERO LINE WOK INDUCTION
COILS & TEMPERATURE SENSORS,
Ø
WOK appliances have a coil
210mm with a single
winding The temperature sensor is part of the coil and
cannot be replaced..
At the center of each coil is located the temperature probe
that acts also as safety probe.
- temperature sensor, if the temperature is spiking over set
point of max temperature (212° ) the safety sensor will slowly
cut down the power of the generator, if the temperature of the
surface does not go down and it reaches 222C° the sensor
will input to shut down the Generator.
There is no manual resetting of the safety sensor , this be-
cause it is electronically controlled; once that the appliance
has cooled down (the appliance will keep in function the ven-
tilation system in case of safety temp. activation) the appli-
ance will turn back on and restart functioning.
In case of overheating an alarm will be displayed on the U.I.
§