A charge roller is used
The cleaning pad always touches the charge roller.
The machine automatically adjusts charge roller voltage for
temperature
The charge roller gives the drum surface a negative charge of approximately -
900V.
The cleaning pad cleans the surface of the charge roller. It always touches the
charge roller. A cam moves the cleaning pad from side to side as the drum turns.
Charge
Charge Roller
81
M080 Training - Sincere-P3
OPC
Cleaning Pad