Hans Grohe Raindance Duschpaneel 27005000 Manual page 25

Hide thumbs Also See for Raindance Duschpaneel 27005000:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 24
Fault
Insufficient water
Crossflow, hot water being forced into
cold water pipe, or vice versa, when
mixer is closed
Spout temperature does not corre-
spond with temperature set
Temperature regulation not possible
Safety stop button not operating
On/off control stiff
English
Cause
- Supply pressure inadequate
- Regulator filter dirty
- Shower filter seal dirty
- Backflow preventers dirty or leaking - Clean backflow preventers, ex-
- Thermostat has not been adjusted
- Hot water temperature too low
- Temperature regulator dirty or calci-
fied
- Spring defective
- Button calcified
- Cartridge on/off control defective,
calcifiedt
Remedy
- Check water pressure (If a pump
has been installed check to see if the
pump is working).
- Clean filters
- Clean filter seal between shower and
hose
change if necessary
- Adjust thermostat
- Increase hot water temperature to 42
°C to 65 °C
- Clean temperature regulator, ex-
change if necessary
- Clean spring and/or button, ex-
change if necessary
- Exchange cartridge on/off control


Advertisement

Table of Contents
loading

Table of Contents