3.4.5 Work area examples
D
B
If the charging station is put in a small area (A),
make sure that the distance to the boundary wire is
at a minimum 3 m / 10 ft.
If the work area has a passage (B), the minimum
distance between the boundary wires is 2 m / 6.6
ft. if no guide wire is installed. With a guide wire
installed through the passage, the minimum
distance between the boundary wires is 60 cm / 24
in.
If the work area has areas which are connected by
a narrow passage (B), you can set the product to
leave the guide wire after a certain distance (C).
The settings can be changed in
page 22 .
If the work area includes a secondary area (D),
To make a secondary area on page 17 .
refer to
Put the product in the secondary area and select
Man .
operating mode

3.5 Installation of the product

3.5.1 Installation tools
Hammer/plastic mallet: To simplify putting the
stakes into the ground.
Edge cutter/straight spade: To bury the boundary
wire.
18 - Installation
3.5.2 To install the charging station
A
C
Remote start 1 on
When connecting the power supply, only use a power
outlet that is connected to a residual-current device
(RCD).
Combination pliers: For cutting the boundary wire
and pressing the connectors together.
Adjustable plier: For pressing the couplers
together.
WARNING:
Obey national regulations
about electrical safety.
WARNING:
The product is only to be
used with the power supply unit supplied by
®
Husqvarna
.
WARNING:
Do not put the power
supply at a height where there is a risk it can
be put in water. Do not put the power supply
on the ground.
WARNING:
Do not encapsulate the
power supply. Condensed water can harm
the power supply and increase the risk of
electrical shock.
WARNING:
Risk of Electric Shock.
Install only to a residual-current device
(RCD) with a tripping current of maximum 30
mA when connecting the power supply to
the power outlet. Applicable to USA/Canada.
If power supply is installed outdoors: Risk of
Electric Shock. Install only to a covered
Class A GFCI receptacle (RCD) that has an
enclosure that is weatherproof with the
attachment plug cap inserted or removed.
CAUTION:
Do not make new holes in
the charging station plate.
CAUTION:
Do not put your feet on the
baseplate of the charging station.
WARNING:
The power supply cable
and extension cable must be outside the
work area to avoid damage to the cables.
1285 - 006 - 17.03.2021