Advertisement

3. INSTALLATION

WARNING:
Nature Power recommends that all wiring be done by a certified technician or
electrician to ensure adherence to the applicable electrical safety wiring regulations and
installation codes. Failure to follow these instructions can damage the unit and could also result in
personal injury or loss of life.
CAUTION:
Before beginning your power inverter Installation, please consider the following:
• The Nature Power Inverter base unit should be used or stored in an indoor area away from
direct sunlight, heat, moisture or conductive contaminants.
• When placing the unit, allow a minimum of three inches of space around the unit for optimal
ventilation.
Understanding the unit features
38304:
Material Prepare for Installation
Typical Wiring block diagram of the Power Inverter:
AC
LOADS
12V Battery Bank:
The use of deep cycle battery is highly recommended for power inverter application
For battery size, you need to identify how much you will be using them between charges.
Nature Power recommends you purchase as much battery capacity as possible. See more
on Battery Run time and Load in Section 4.
Fuse or Circuit Breaker:
DC-rated fuse or DC-rated circuit breaker connected along the DC positive line is required.
Select a fuse or circuit breaker with a minimum of 60 ADC
Based on the size of the battery bank chosen on the 12V Battery Bank above, determine the
overall short circuit current rating of the battery bank from the battery manufacturer. The fuse
or circuit breaker chosen has to be able to withstand the short circuit current that may be
generated by the battery bank.
Disconnect Switch:
Select a Disconnect Switch with the same or higher the rating of the selected fuse or circuit
breaker from the above.
The Disconnect Switch is used to disconnect the DC power between the power inverter and
the battery bank during service, maintenance or trouble shooting.
Pos +
Power Inverter
Neg -
38304
38204
38204:
'Power' indicator
'Fault' indicator
USB
On/Off Switch
Fan opening
DC Input Terminals
Disconnect
Switch
Page 3 of 8
Fuse or Circuit
12 V Battery Bank
Breaker
sold separately is
required to charge
the battery bank
when battery is
discharged)
(Charger system