testo Saveris multifunction handle
0560 1020
Instruction manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Saveris 0560 1020 and is the answer not in the manual?

Questions and answers

Drew Oliver
June 19, 2025

How do I change my thermometer Testo Sevaria 0560 from Celsius to Fahrenheit?

Rosie
May 12, 2025

How do I change it from c to f

Subscribe to Our Youtube Channel

Summary of Contents for TESTO Saveris 0560 1020

  • Page 1 Saveris multifunction handle 0560 1020 Instruction manual...
  • Page 3: Table Of Contents

    Hold function ..................13 8.3.6 Vibration signal ..................13 Operation .................... 13 Fitting probe measuring tips onto the testo Saveris multifunction handle ....................14 Carrying out measurements ..............14 9.2.1 Measurements with the standard version of the multifunction handle .. 14 9.2.1.1 Measurements with Auto-Hold function enabled ........
  • Page 4 9.2.3.2 testo Saveris cooking oil probe ............18 9.2.3.3 testo Saveris surface temperature probe ..........19 9.2.3.4 testo Saveris air temperature probe ............. 19 9.2.3.5 testo Saveris TC adapter (type K) ............19 Maintenance and care ............... 20 10.1 Changing the battery ................20 10.2...
  • Page 5: About This Document

    Please refer to the separate document Testo information. 3 Product-specific approvals For the current country approvals (Approval and Certification), please refer to the document enclosed with the product testo Saveris multifunction handle (order number 0971 2613). 4 Support You can find up-to-date information on products, downloads and links to contact...
  • Page 6: Scope Of Delivery

    3 4 x AA batteries 4 Screwdriver 6 Use The testo Saveris multifunction handle is equipped with a display and transmits the measurement data, which is generated with interchangeable probe ® measuring tips, to a mobile device via an existing Bluetooth connection.
  • Page 7: Testo Saveris Multifunction Handle Instrument Description

    7 testo Saveris multifunction handle instrument description 7 testo Saveris multifunction handle instrument description 7.1.1 Overview Element Element 1 Connection for probe measuring 2 Display tips Send button On/Off/Hold button 5 Battery compartment (on rear) 7.1.2 Displays Display Function/property Battery capacity 100 %...
  • Page 8: Probe Measuring Tips (Not Included In The Scope Of Delivery)

    Reading outside the measuring range Probe measuring tips (not included in the scope of delivery) The testo Saveris multifunction handle and the attached probe measuring tips together form a handy measuring instrument for fast temperature measurement and cooking oil testing.
  • Page 9: Testo Saveris Penetration Temperature Probes

    7 testo Saveris multifunction handle instrument description 6 testo Saveris TC adapter (type K) testo Saveris penetration temperature probes Overview Element Element 1 Connection plug 2 Union nut 3 Penetration temperature probe with thermocouple (TC) The penetration temperature probe enables core temperature measurements to be carried out in food.
  • Page 10: Testo Saveris Cooking Oil Probe

    2 Union nut 3 Sensor With the testo Saveris cooking oil probe, the total polar materials (TPM value) is determined as a percentage. The TPM value enables a statement to be made on the ageing of the cooking oil due to the effects of heat.
  • Page 11: Testo Saveris Surface Temperature Probe

    The reference value must be determined again if the type of oil or oil supplier changes. Where there are implausible readings, we recommend calibration or adjustment in testo reference oil (order number 0554 2650). testo Saveris surface temperature probe Overview...
  • Page 12: Testo Saveris Air Temperature Probe

    7 testo Saveris multifunction handle instrument description testo Saveris air temperature probe Overview Element Element 1 Connection plug 2 Union nut 3 Air temperature probe The air temperature probe allows air temperatures to be measured in refrigerators and freezers. Readings can be generated even with the door closed, thanks to the flexible, robust cable.
  • Page 13: Commissioning

    8 Commissioning Element Element 1 Connection plug 2 Union nut 3 TC connector The TC adapter enables instruments with TC interfaces to be validated. To do this, you compare the value displayed on the equipment with the measured value. 8 Commissioning Inserting / changing batteries Undo the screws on the battery compartment using the screwdriver...
  • Page 14: Mounting The Wall Bracket

    8.3.1 Switching on the testo Saveris multifunction handle  The batteries are inserted into the testo Saveris multifunction handle, are fully charged and have sufficient capacity. Fit the probe measuring tip (see section 9.1). Press the key to switch on the testo Saveris multifunction handle.
  • Page 15: Auto-Off Function

    When the Auto-Hold function is enabled, Auto and the current measuring value flash on the display of the testo Saveris multifunction handle. The measured values are automatically held by the instrument after the acclimatization time. The generated measuring value and Auto-Hold are shown on the display.
  • Page 16: Fitting Probe Measuring Tips Onto The Testo Saveris Multifunction Handle

    Saveris multifunction handle. (Insert with the label at the top.) Screw the probe measuring tip securely onto the testo Saveris multifunction handle using the union nut.  Measurements can now be carried out.
  • Page 17: Measurements With Auto-Hold Function Disabled

    The required probe measuring tip is fitted and the testo Saveris multifunction handle is switched on. Position the probe measuring tip in or on the medium being measured. Wait until the reading on the display of the testo Saveris multifunction handle has stabilized.  The reading stops changing.
  • Page 18: Measuring With Temperature Stabilization Mode (Tts)

    9 Operation > Position the probe measuring tip in or on the medium being measured.  The current measurement value is shown. Values measured in real-time mode cannot be transmitted and thus cannot be saved. To do this, please switch to temperature stabilization mode (TTS).
  • Page 19: Special Information For Measurement

    - In the event of burns, immediately cool the relevant spot with cold water and consult a doctor if necessary. 9.2.3.1 testo Saveris penetration temperature probes Carefully place the penetration temperature probe in the medium and carry out the measurement. This should involve a minimum penetration depth of 10 mm.
  • Page 20 “Temperature skeining” in the oil may cause measurement errors. Move probe measuring tip in the deep fryer.  Cooking oil probe is fitted onto the testo Saveris multifunction handle. Immerse the sensor in hot oil. Pay attention to min/max marks! Move the probe measuring tip in small circles.
  • Page 21 Otherwise this may result in measuring inaccuracies.  The surface temperature probe is fitted onto the testo Saveris multifunction handle. Position the measuring head flatly on the surface. Apply pressure to the probe measuring head by way of the flexible shaft (do not press down probe measuring head directly by hand).
  • Page 22: Maintenance And Care

    10.2 Cleaning the testo Saveris multifunction handle Only use weak, commercially available neutral/household cleaning agents (e.g. washing-up liquid) to clean the testo Saveris multifunction handle. Do not use aggressive cleaning agents or solvents! Only clean the testo Saveris multifunction handle, including contact, gently with a soft paper towel.
  • Page 23: Testo Saveris Penetration Temperature Probes

    Only clean sensor gently with a soft paper towel or rinse under running water. Carefully dry sensor with a soft paper towel. 10.3.2 testo Saveris cooking oil probe ATTENTION Improper handling! Damage to the sensor possible! - Do not remove cold oil residues from the sensor.
  • Page 24: Testo Saveris Tc Adapter (Type K)

    11 Questions and answers Carefully dry air temperature probe with a soft paper towel. 10.3.4 testo Saveris TC adapter (type K) Only clean TC adapter (type K) gently with a soft paper towel or rinse under running water. Carefully dry TC adapter (type K) with a soft paper towel.
  • Page 25: Technical Data

    12 Technical data If we were not able to answer your question, please contact Testo Customer Service. See the back of this document or the www.testo.com/service-contact web page for contact details. 12 Technical data Feature Value Resolution Temperature: 0.1 °C/0.1 °F Measurement unit °C/°F...