Hold function ..................13 8.3.6 Vibration signal ..................13 Operation .................... 13 Fitting probe measuring tips onto the testo Saveris multifunction handle ....................14 Carrying out measurements ..............14 9.2.1 Measurements with the standard version of the multifunction handle .. 14 9.2.1.1 Measurements with Auto-Hold function enabled ........
Page 4
9.2.3.2 testo Saveris cooking oil probe ............18 9.2.3.3 testo Saveris surface temperature probe ..........19 9.2.3.4 testo Saveris air temperature probe ............. 19 9.2.3.5 testo Saveris TC adapter (type K) ............19 Maintenance and care ............... 20 10.1 Changing the battery ................20 10.2...
Please refer to the separate document Testo information. 3 Product-specific approvals For the current country approvals (Approval and Certification), please refer to the document enclosed with the product testo Saveris multifunction handle (order number 0971 2613). 4 Support You can find up-to-date information on products, downloads and links to contact...
3 4 x AA batteries 4 Screwdriver 6 Use The testo Saveris multifunction handle is equipped with a display and transmits the measurement data, which is generated with interchangeable probe ® measuring tips, to a mobile device via an existing Bluetooth connection.
Reading outside the measuring range Probe measuring tips (not included in the scope of delivery) The testo Saveris multifunction handle and the attached probe measuring tips together form a handy measuring instrument for fast temperature measurement and cooking oil testing.
7 testo Saveris multifunction handle instrument description 6 testo Saveris TC adapter (type K) testo Saveris penetration temperature probes Overview Element Element 1 Connection plug 2 Union nut 3 Penetration temperature probe with thermocouple (TC) The penetration temperature probe enables core temperature measurements to be carried out in food.
2 Union nut 3 Sensor With the testo Saveris cooking oil probe, the total polar materials (TPM value) is determined as a percentage. The TPM value enables a statement to be made on the ageing of the cooking oil due to the effects of heat.
The reference value must be determined again if the type of oil or oil supplier changes. Where there are implausible readings, we recommend calibration or adjustment in testo reference oil (order number 0554 2650). testo Saveris surface temperature probe Overview...
7 testo Saveris multifunction handle instrument description testo Saveris air temperature probe Overview Element Element 1 Connection plug 2 Union nut 3 Air temperature probe The air temperature probe allows air temperatures to be measured in refrigerators and freezers. Readings can be generated even with the door closed, thanks to the flexible, robust cable.
8 Commissioning Element Element 1 Connection plug 2 Union nut 3 TC connector The TC adapter enables instruments with TC interfaces to be validated. To do this, you compare the value displayed on the equipment with the measured value. 8 Commissioning Inserting / changing batteries Undo the screws on the battery compartment using the screwdriver...
8.3.1 Switching on the testo Saveris multifunction handle The batteries are inserted into the testo Saveris multifunction handle, are fully charged and have sufficient capacity. Fit the probe measuring tip (see section 9.1). Press the key to switch on the testo Saveris multifunction handle.
When the Auto-Hold function is enabled, Auto and the current measuring value flash on the display of the testo Saveris multifunction handle. The measured values are automatically held by the instrument after the acclimatization time. The generated measuring value and Auto-Hold are shown on the display.
Saveris multifunction handle. (Insert with the label at the top.) Screw the probe measuring tip securely onto the testo Saveris multifunction handle using the union nut. Measurements can now be carried out.
The required probe measuring tip is fitted and the testo Saveris multifunction handle is switched on. Position the probe measuring tip in or on the medium being measured. Wait until the reading on the display of the testo Saveris multifunction handle has stabilized. The reading stops changing.
9 Operation > Position the probe measuring tip in or on the medium being measured. The current measurement value is shown. Values measured in real-time mode cannot be transmitted and thus cannot be saved. To do this, please switch to temperature stabilization mode (TTS).
- In the event of burns, immediately cool the relevant spot with cold water and consult a doctor if necessary. 9.2.3.1 testo Saveris penetration temperature probes Carefully place the penetration temperature probe in the medium and carry out the measurement. This should involve a minimum penetration depth of 10 mm.
Page 20
“Temperature skeining” in the oil may cause measurement errors. Move probe measuring tip in the deep fryer. Cooking oil probe is fitted onto the testo Saveris multifunction handle. Immerse the sensor in hot oil. Pay attention to min/max marks! Move the probe measuring tip in small circles.
Page 21
Otherwise this may result in measuring inaccuracies. The surface temperature probe is fitted onto the testo Saveris multifunction handle. Position the measuring head flatly on the surface. Apply pressure to the probe measuring head by way of the flexible shaft (do not press down probe measuring head directly by hand).
10.2 Cleaning the testo Saveris multifunction handle Only use weak, commercially available neutral/household cleaning agents (e.g. washing-up liquid) to clean the testo Saveris multifunction handle. Do not use aggressive cleaning agents or solvents! Only clean the testo Saveris multifunction handle, including contact, gently with a soft paper towel.
Only clean sensor gently with a soft paper towel or rinse under running water. Carefully dry sensor with a soft paper towel. 10.3.2 testo Saveris cooking oil probe ATTENTION Improper handling! Damage to the sensor possible! - Do not remove cold oil residues from the sensor.
11 Questions and answers Carefully dry air temperature probe with a soft paper towel. 10.3.4 testo Saveris TC adapter (type K) Only clean TC adapter (type K) gently with a soft paper towel or rinse under running water. Carefully dry TC adapter (type K) with a soft paper towel.
12 Technical data If we were not able to answer your question, please contact Testo Customer Service. See the back of this document or the www.testo.com/service-contact web page for contact details. 12 Technical data Feature Value Resolution Temperature: 0.1 °C/0.1 °F Measurement unit °C/°F...
Need help?
Do you have a question about the Saveris 0560 1020 and is the answer not in the manual?
Questions and answers
How do I change my thermometer Testo Sevaria 0560 from Celsius to Fahrenheit?
How do I change it from c to f