12 Technical data

Feature
Resolution
Measurement unit
Temperature measuring
range
Temperature accuracy
Power supply (battery)
Battery life
Operating temperature
Ambient humidity
Storage/transport
temperature
Display
Dimensions
Weight
Protection class
Approvals/guidelines
Value
Temperature: 0.1 °C/0.1 °F
°C/°F
-30 to 260 °C/-22 to 500 °F
±0.3 °C (-30 to 70 °C);
remaining range: ±(0.3 °C + 0.5% of measured
value), in each case ± digit
(Note: accuracy of the individual temperature
probes is added up)
4 x AA Mignon batteries: Designation according
to IEC: LR03, chem. composition: Zn-MnO²
(alkaline)
150 h (typical operation:
approx. 35,000 TC measurements and
approx. 7,000 cooking oil measurements)
25 h (continuous operation)
-20 to 50 °C/-4 to 122 °F
0 to 90 %RH
-30 to 70 °C/-22 to 158 °F (without batteries)
LCD, 2-cell
170 mm x 50 mm x 37 mm
220 g
IP65 (with probe measuring tip)
NSF/ANSI 2
EN13485 (E); 0.5 (penetration probe) or 1.0 (air
probe),
Regulation 1935/2004
REACH/RohS