In the unlikely event that you should experience any problems with your systems, please contact LINAK Danmark A/S on +45 8680 3611. LINAK provides a warranty on all its products and systems. However, this warranty is provided on condition that the product is used in accordance with the applicable specifications, that maintenance is performed correctly, and that any repairs are carried out at a workshop that is authorised to repair LINAK products.
The warranty is limited to the value of the LINAK product. The LINAK warranty shall only apply if the system has been used correctly and has not been opened. The control box and control unit must not be exposed to violent use. Failure to comply with this requirement will void the warranty.
Page 4
The equipment is not suitable for use in the immediate vicinity of a flammable, anaesthetic mixture involving air, oxygen or laughing gas (nitrous oxide). Environmental conditions: Page 4 of 44 june 2020 ver.11 LINAK Danmark A/S Mønstedsvej 9 DK-8600 Silkeborg Tel. +45 8680 3611 Fax: +45 86829051 linak@linak-silkeborg.dk www.linak.dk...
Page 5
Warning! The plastic components in the system cannot withstand cutting oil. Page 5 of 44 june 2020 ver.11 LINAK Danmark A/S Mønstedsvej 9 DK-8600 Silkeborg Tel. +45 8680 3611 Fax: +45 86829051 linak@linak-silkeborg.dk www.linak.dk...
The TECH-system type 273 is an actuator system that has been developed for industrial purposes consisting of up to four LINAK actuators. The system uses a specially designed motor control unit to ensure that the actuators operate safely and in parallel. The TECH-system type 273 is suitable for applications for very heavy lifts of up to 2000 kg total weight.
Duty% = Duty% @ T25 x The power supply unit is available as a separate unit: Order no. TR-EM-000-T-230-700 Page 8 of 44 june 2020 ver.11 LINAK Danmark A/S Mønstedsvej 9 DK-8600 Silkeborg Tel. +45 8680 3611 Fax: +45 86829051 linak@linak-silkeborg.dk www.linak.dk...
Order no. TR-1939.3314-00 • Rocker switch for building in: Other types of control devices can also be used. Page 9 of 44 june 2020 ver.11 LINAK Danmark A/S Mønstedsvej 9 DK-8600 Silkeborg Tel. +45 8680 3611 Fax: +45 86829051 linak@linak-silkeborg.dk www.linak.dk...
Motor control unit TR-EM-273 as separate PCB TR-EM-273 motor control unit fitted in a plastic box with built-in power supply Weight 7.5 kg Page 10 of 44 june 2020 ver.11 LINAK Danmark A/S Mønstedsvej 9 DK-8600 Silkeborg Tel. +45 8680 3611 Fax: +45 86829051 linak@linak-silkeborg.dk www.linak.dk...
Page 11
TR-EM-273 mounted in plastic housing without for incorporating into an electrical panel power supply Weight: approx. 200 gram Weight: approx. 300 gram Page 11 of 44 june 2020 ver.11 LINAK Danmark A/S Mønstedsvej 9 DK-8600 Silkeborg Tel. +45 8680 3611 Fax: +45 86829051 linak@linak-silkeborg.dk www.linak.dk...
Instruction Manual for TECH-system type 273 Rating plate and labelling Rating plate on TR-EM-273 control unit: Rating plate on actuator LA31 w/Reed Page 12 of 44 june 2020 ver.11 LINAK Danmark A/S Mønstedsvej 9 DK-8600 Silkeborg Tel. +45 8680 3611 Fax: +45 86829051 linak@linak-silkeborg.dk www.linak.dk...
The PCB is fitted using five 3 mm diameter screws and connected to an external power supply. The height of the PCB is 25 mm. Page 14 of 44 june 2020 ver.11 LINAK Danmark A/S Mønstedsvej 9 DK-8600 Silkeborg Tel. +45 8680 3611 Fax: +45 86829051 linak@linak-silkeborg.dk www.linak.dk...
Page 15
PCB fitted on DIN rail for panel installation – TR-EM-273-R The PCB is mounted on a DIN rail and connected to an external power supply. Page 15 of 44 june 2020 ver.11 LINAK Danmark A/S Mønstedsvej 9 DK-8600 Silkeborg Tel. +45 8680 3611 Fax: +45 86829051 linak@linak-silkeborg.dk www.linak.dk...
Page 16
The box is fitted using four screws and the power supply unit is connected to mains voltage as shown below. Fuse Connect mains voltage to the transformer Page 16 of 44 june 2020 ver.11 LINAK Danmark A/S Mønstedsvej 9 DK-8600 Silkeborg Tel. +45 8680 3611 Fax: +45 86829051 linak@linak-silkeborg.dk www.linak.dk...
DC-DC converter Order no.: EM-311-DK Installing the DC-DC converter: To connect the converter, see diagram on page 25. Page 17 of 44 june 2020 ver.11 LINAK Danmark A/S Mønstedsvej 9 DK-8600 Silkeborg Tel. +45 8680 3611 Fax: +45 86829051 linak@linak-silkeborg.dk www.linak.dk...
Terminal 24: Analog input for signal to positioning (servo). Use parameter 2 to select 0–5 V or 0–10 Terminal 25: 5 V control voltage. Page 18 of 44 june 2020 ver.11 LINAK Danmark A/S Mønstedsvej 9 DK-8600 Silkeborg Tel. +45 8680 3611 Fax: +45 86829051 linak@linak-silkeborg.dk www.linak.dk...
For additional information, please refer to the data sheet for the actuator in question. Connection of LINAK actuators The majority of LINAK actuators are supplied as standard with a pre-fitted cable, and the actuators are also fitted with different types of plugs depending on which control box has been selected for the control operations.
Page 20
LA35 LA36 Motor cable Order no. 0367002-1500 Signal cable Signal cable Order no. 0367003-1500 Order no. 0367003-1500 Page 20 of 44 june 2020 ver.11 LINAK Danmark A/S Mønstedsvej 9 DK-8600 Silkeborg Tel. +45 8680 3611 Fax: +45 86829051 linak@linak-silkeborg.dk www.linak.dk...
Instruction Manual for TECH-system type 273 Connection diagram for LINAK actuators The following pages present diagrams for the various types of actuators, along with LINAK's recommended parameter values • Actuator LA12 w/reed switch Actuator LA14/LA25 w/hall potentiometer • Actuator LA20 w/hall sensor •...
LA12 - Reed Ordering no. for a Unit ready to run with LA12 Reed: TREM-0000-0014-DK LA14/25– Hall pot. Page 22 of 44 june 2020 ver.11 LINAK Danmark A/S Mønstedsvej 9 DK-8600 Silkeborg Tel. +45 8680 3611 Fax: +45 86829051 linak@linak-silkeborg.dk www.linak.dk...
Use the White wire for Actuators 25 = 255 produced before 15-10-2014 26 = 10 27 = 10 28 = Learn Page 28 of 44 june 2020 ver.11 LINAK Danmark A/S Mønstedsvej 9 DK-8600 Silkeborg Tel. +45 8680 3611 Fax: +45 86829051 linak@linak-silkeborg.dk www.linak.dk...
BACK Green Orange DP1T + TP1 FORWARD BACK Green Blue Rocker switch FORWARD Reset / initialisation BACK Page 29 of 44 june 2020 ver.11 LINAK Danmark A/S Mønstedsvej 9 DK-8600 Silkeborg Tel. +45 8680 3611 Fax: +45 86829051 linak@linak-silkeborg.dk www.linak.dk...
(Cables on a wired Hand control with cable lengths above 5 m) Example with HB41T 10-35Vdc Green Orange PLC- supply -GND Page 31 of 44 june 2020 ver.11 LINAK Danmark A/S Mønstedsvej 9 DK-8600 Silkeborg Tel. +45 8680 3611 Fax: +45 86829051 linak@linak-silkeborg.dk www.linak.dk...
Once you have made the changes you require, save the new configuration by pressing ARROW UP for at least 2 seconds. Page 32 of 44 june 2020 ver.11 LINAK Danmark A/S Mønstedsvej 9 DK-8600 Silkeborg Tel. +45 8680 3611 Fax: +45 86829051 linak@linak-silkeborg.dk www.linak.dk...
NB! LINAK's recommended parameter values are stated on the connection diagrams for the individual actuators, which are presented later in this document. Page 33 of 44 june 2020 ver.11 LINAK Danmark A/S Mønstedsvej 9 DK-8600 Silkeborg Tel. +45 8680 3611 Fax: +45 86829051 linak@linak-silkeborg.dk www.linak.dk...
The speed is stated in %, where 100% is the max. speed. The following options are available: 0 to 100 Page 34 of 44 june 2020 ver.11 LINAK Danmark A/S Mønstedsvej 9 DK-8600 Silkeborg Tel. +45 8680 3611 Fax: +45 86829051 linak@linak-silkeborg.dk www.linak.dk...
Page 35
The delay is measured in milliseconds from 5–20 ms. The following options are available: 5 to 20 Page 35 of 44 june 2020 ver.11 LINAK Danmark A/S Mønstedsvej 9 DK-8600 Silkeborg Tel. +45 8680 3611 Fax: +45 86829051 linak@linak-silkeborg.dk www.linak.dk...
Page 36
In a 4-parallel system, all actuators must be connected. This means that parameters 18, 19, 20 and 21 must be set to 1. Disconnected motors will not operate. Page 36 of 44 june 2020 ver.11 LINAK Danmark A/S Mønstedsvej 9 DK-8600 Silkeborg Tel. +45 8680 3611 Fax: +45 86829051 linak@linak-silkeborg.dk www.linak.dk...
Page 37
The following options are available: 30 to 32767 Page 37 of 44 june 2020 ver.11 LINAK Danmark A/S Mønstedsvej 9 DK-8600 Silkeborg Tel. +45 8680 3611 Fax: +45 86829051 linak@linak-silkeborg.dk www.linak.dk...
Example: Actuator LA36 for 6800N and a stroke length of 600 mm = 600/0.4 = 1500 pulses for the full stroke length Page 38 of 44 june 2020 ver.11 LINAK Danmark A/S Mønstedsvej 9 DK-8600 Silkeborg Tel. +45 8680 3611 Fax: +45 86829051 linak@linak-silkeborg.dk www.linak.dk...
• • The system must not be used until it is incorporated into the end product. Page 39 of 44 june 2020 ver.11 LINAK Danmark A/S Mønstedsvej 9 DK-8600 Silkeborg Tel. +45 8680 3611 Fax: +45 86829051 linak@linak-silkeborg.dk www.linak.dk...
10 error codes. In the main menu, use ARROW DOWN to select the “Monitor Values” menu item. Page 40 of 44 june 2020 ver.11 LINAK Danmark A/S Mønstedsvej 9 DK-8600 Silkeborg Tel. +45 8680 3611 Fax: +45 86829051 linak@linak-silkeborg.dk www.linak.dk...
6. The full stroke length learned is then measured and saved with a value range of 0–1023 (Parameter 28). The system is now ready for use. Page 41 of 44 june 2020 ver.11 LINAK Danmark A/S Mønstedsvej 9 DK-8600 Silkeborg Tel. +45 8680 3611 Fax: +45 86829051 linak@linak-silkeborg.dk www.linak.dk...
ARROW UP and ARROW DOWN). All errors are reset when the power supply is interrupted. Page 43 of 44 june 2020 ver.11 LINAK Danmark A/S Mønstedsvej 9 DK-8600 Silkeborg Tel. +45 8680 3611 Fax: +45 86829051 linak@linak-silkeborg.dk www.linak.dk...
Instruction Manual for TECH-system type 273 Disposal of LINAK products To dispose of LINAK products, start by sorting them into different categories for recycling or incineration. We recommend that you dismantle your product as fully as possible for disposal, and that you reuse the parts.