- The electrical installation must include a double pole switch, with a contact
clearance of at least 3 mm, correctly sized and in accordance with the electrical
standards.

5.- USE AND MAINTENANCE

We recommend that the extractor is left running for about 15 minutes after
cooking has finished in order to completely exhaust all of the stale air.
The correct operation of the extractor depends on regular maintenance,
especially for those models fitted with a grease filter (CK-40F & CK-60F).
ATTENTION: Before cleaning the extractor make sure that the fan blade
has completely stopped.
Clean regularly to remove all the grease deposits, on the inside and outside of
the extractor. All the components should be cleaned at least every two months.
Cleaning is simple and can be carried out without the need for any tools. To
proceed, first remove the grease tray by sliding it out on its runners (Fig.5). Then
withdraw the screw from the bottom and the outside cover by pressing on the
side buttons. Once the cover is off, unscrew the fan blade (Fig.6).
To clean the scroll, simply wipe it with a damp cloth soaked in household
nonabrasive detergent.
The CK-40F and CK-60F units, are fitted with filters which are designed to retain
the grease particles this of course means that they will become dirty through use
of the extractor.
At least every two months, clean the filter following the instructions set out below:
- First remove the external cover, then release the filter from the cover by
loosening the plastic nuts which are on the inside (Fig.7).
- Wash the filter with water and a mild detergent.
- Rinse thoroughly and leave to dry before fitting back into the cover.
- Plastic parts and metal filter can be introduced into dishwasher if washing
temperature and drying does not exceed to 60ºC.
- Failure to follow this maintenance procedure could cause a fire risk should a
flame come near or into contact with the filter.
ATTENTION: In some circumstances household electrical appliances can
be dangerous.
- Do not remove the external cover while the extractor is running.