22
Revised 09 .15 .11
4
Remove the 2 screws that hold the Bimetal Switch/
Sensor Fixing Mat to the Metal Bottom Plate .
Remove the Transformer wires from below it .
5
Remove 3 connectors from Transformer to Main
PCB .
Mat Screws
6
Remove the 4 screws that hold the Transformer to
the Metal Bottom Plate .
7
Place new Transformer and secure it with the 4
screws .
8
Attach the wires to Main PCB and secure them with
the wire holders .
9
Replace the Bimetal Switch/Sensor Fixing Mat and
secure it with the 2 screws .
10
Connect the power and grounding wires to the Noise
Filter .
11
Replace Roller Assembly .