The available settings in the email notification settings screen are shown below.
Enable email
Check the box to use email notification.
notification
Email Address
Click New to add a new email address. An existing address can be changed by selecting the
address and clicking Edit. An address can be deleted by selecting the address and clicking
Delete.
A maximum of five addresses can be set for receiving notification.
SMTP Server
In Server address, enter the SMTP server address (mail server address).
In Port, enter the SMTP port number.
Note: Unless specified otherwise, the standard port (25) is used. Also, if Authentication setup is
set to None or POP before SMTP, the standard port number (25) is used regardless of the number
entered in this box.
Authentication
The User Authentication can be selected from POP before SMTP, LOGIN (SMTP-AUTH/LOGIN), and
CRAM-MD5 (SMTP-AUTH/CRAM-MD5).
If POP before SMTP is selected, enter the POP server address (mail server address) and port
number.
Note: Unless specified otherwise, the standard port (110) is used. Enter the username and
password for your email account.
SSL/TLS
If LOGIN (SMTP-AUTH/LOGIN) or CRAM-MD5 (SMTP-AUTH/CRAM-MD5) is selected in the
Authentication setup, specify whether to use SSL or TLS.
Title
Enter a subject line for your notification emails here.
Note: Use single-byte characters only. Two-byte characters will not be displayed correctly.
Contents
Email Server Address: Check to add IPv6 compatibility to email notifications.
Select what events trigger an email notification.
Status report: The TeraStation's hostname and IP address are mailed at the selected time.
Disk error: An email is sent when an error occurs in the TeraStation hard drive.
At boot: An email is sent when the system is booted or restarted.
Fan failure: An email is sent when an error occurs with the TeraStation's fan.
Backup error: An email is sent if an error occurs during backup.
Replication error: An email is sent if an error occurs during replication.
Temperature error: An email is sent if the TeraStation overheats.
PSU failure: An email is sent when the PSU (Power Supply Unit) fails*.
Note: This notification is not supported for the TeraStation WS-VL series at this time.
Specify event ID: Enter an event ID to trigger email notifications.
Test Message
This sends a test email using the current settings.
Apply
This applies the current settings.
Close
This closes the email notification settings screen.