Adjustments - Assa Abloy RIXSON 93 Quick Start Manual

Overhead concealed closer
Table of Contents

Advertisement

Model 93, Metal Frame

Adjustments

Speed Adjustment
Use provided 1/8" hex wrench to adjust
sweep, latch and backcheck valves to control
speed of door. (Figure 17)
NEVER completely close backcheck valve.
NEVER use backcheck as a dead stop.
NEVER fully open valves. Valves will leak.
Do not use a power drill.
Warranty will be void.
Closing Force Adjustment
If additional force is needed, use 3/8" hex
wrench to adjust closing force. (Figure 18)
Do not use a power drill.
Warranty will be void.
All 93 Series closers are factory set to
minimum force. Adjust closer as
necessary for more force taking into
consideration door size, weight, positive
room pressure, etc.
Optional Hold Open Adjustment
1.
Insert locking tab of hold open assembly
into track slider. (Figure 19)
NOTE: Hold open assembly should be
on hinge side of track slider.
2.
Open door to desired hold open position.
3.
Tighten hold open set screws to lock
down hold open assembly.
4.
Pull door in closing direction to
disengage hold open assembly and track
slider.
5.
Adjust hold open by turning adjustment
screw with provided 3/16" hex wrench.
NOTE: THIS FEATURE CANNOT BE USED ON
FIRE-RATED DOORS
Copyright © 2021, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole or in
part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
IS93 07/21
Figure 17
Spring Power Adjustment for Closing Force
(Closer shipped at lowest setting)
Model PH93
Closer
Approx # of
Size
360° Turns
ADA
1
2
3
Figure 18
Figure 19
75°
Backcheck
Sweep Speed
Model 93
Closer
Approx # of
Size
360° Turns
0
3
15
4
17
30
5
25
55
6
32
Latch Speed
0
9

Advertisement