PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
REFILL - Range: 20 to 230
This function allows the operator to adjust the
sensitivity of the refill circuit. This is mainly a trouble-
shooting feature. Water in different geographical loca-
tions can have different conductivities. By adjusting
the sensitivity of the refill circuit, this will allow the
brewer to operate under various water conditions.
Procedure to set the sensitivity threshold of the refill
circuit:
NOTE: Make sure the water in the tank is touching the
refill probe.
1. Press and hold the ® until the display reads
WARMER OFF. Release the ®. Press and release
the ® pad until the display reads REFILL and
shows a number on both sides of the word.
2. To adjust the threshold setting, press (-) to de-
crease, or (+) to increase the setting.
NOTE: Always make sure that the number on the right
is larger than the number on the left when water is in
contact with the refill probe in the tank.
3. When finished, press and release DONE. This
saves the new setting and advances to the next
function screen, SPRAY MI/M. Another alterna-
tive is to press the "ON/OFF/LOWER" pad located
on the front switch panel to exit REFILL and return
to the MAIN SCREEN.
SPRAY MI/M
This function allows the operator to view or to
enter the actual flow rate coming out of the sprayhead.
This is NOT used to change the actual flow rate, but to
tell the internal controller how fast the water is flowing.
The unit of measure is ounces per minute. (Ml/M)
SPRAY MI/M: XX.X
(-)
DONE
Procedure to adjust the flow rate setting:
1. Press and hold the ® pad until the display reads
2. If the actual flow rate of the sprayhead valve is
3. When finished, press and release DONE. This
P2304
DILUTE MI/M
enter the actual flow rate coming out of the dilution
nozzle. This is NOT used to change the actual flow rate,
but to tell the internal controller how fast the water is
flowing. The unit of measure is ounces per minute.
Procedure to adjust the flow rate setting:
1. Press and hold the ® pad until the display reads
2. If the actual flow rate of the dilution valve is known,
3. When finished, press and release the DONE pad.
(+)
P3221
Page 31
WARMER OFF. Release the ®. Press and release
the ® pad until the display reads SPRAY MI/M. The
number represents what the brewer thinks is the
flow rate of the sprayhead valve in ounces per
minute.
known, but is different than the number on the
display, use the (-) and (+) pads to enter the
correct flow rate in ounces per minute.
saves the new setting and advances to the next
function screen, DILUTE MO/M. Another alterna-
tive is to press the "ON/OFF/LOWER" pad located
on the switch panel to exit SPRAY MI/M function
and return to the MAIN SCREEN.
This function allows the operator to view or to
DILUTE MI/M: XX.X
(-)
DONE
WARMER OFF. Release the ®. Press and release
the ® pad until the display reads DILUTE MI/M.
The number represents what the brewer thinks is
the flow rate of the dilution valve in ounces per
minute.
but is different than the number on the display, use
the (-) and (+) pads to enter the correct flow rate
in ounces per minute.
This saves the new setting and advances to the
next function screen, CALIBRATE FLOW. Another
alternative is to press the "ON/OFF/LOWER" pad
located on the front switch panel to exit the DILUTE
MI/M function and return to the MAIN SCREEN.
(+)
P3222
37467 110904