PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
REFILL - Range: 20 to 230
This function allows the operator to adjust the
sensitivity of the refill circuit. This is mainly a trouble-
shooting feature. Water in different geographical loca-
tions can have different conductivities. By adjusting
the sensitivity of the refill circuit, this will allow the
brewer to operate under various water conditions.
XXX
REFILL
(-)
DONE
Procedure to set the sensitivity threshold of the
refill circuit:
NOTE: Make sure the water in the tank is touching
the refill probe.
1. Press and hold the ® until the display reads SET
NEW RECIPES. Release the ®. Press and release
the ® pad until the display reads REFILL and shows
a number on both sides of the word.
2. To adjust the threshold setting, press (-) to de-
crease, or (+) to increase the setting.
NOTE: Always make sure that the number on the right
is larger than the number on the left when water is in
contact with the refill probe in the tank.
3. When finished, press and release DONE. This
saves the new setting and advances to the next
function screen, SPRAY OZ/M. Another alterna-
tive is to press the
switch panel to exit REFILL and return to the MAIN
SCREEN.
SPRAY OZ/M
This function allows the operator to view or to enter
the actual flow rate coming out of the sprayhead. This
is NOT used to change the actual flow rate, but to tell
the internal controller how fast the water is flowing.
The unit of measure is ounces per minute. (Oz/M)
SPRAY OZ/M: XX.X
(-)
DONE
Procedure to adjust the flow rate setting:
1. Press and hold the ® pad until the display reads
XXX
(+)
P2304
pad located on the front
(+)
P2305
Page 28
SET NEW RECIPES. Release the ®. Press and
release the ® pad until the display reads SPRAY
OZ/M. The number represents what the brewer
thinks is the flow rate of the sprayhead valve in
ounces per minute.
2. If the actual flow rate of the sprayhead valve is
known, but is different than the number on the
display, use the (-) and (+) pads to enter the cor-
rect flow rate in ounces per minute.
3. When finished, press and release DONE. This saves
the new setting and advances to the next function
screen, BYPASS OZ/M. Another alternative is to
press the
pad located on the switch panel to
exit SPRAY OZ/M function and return to the MAIN
SCREEN.
BYPASS OZ/M
This function allows the operator to view or to enter
the actual flow rate coming out of the bypass nozzle.
This is NOT used to change the actual flow rate, but to
tell the internal controller how fast the water is flowing.
The unit of measure is ounces per minute.
BYPASS OZ/M: XX.X
(-)
DONE
Procedure to adjust the flow rate setting:
1. Press and hold the ® pad until the display reads SET
NEW RECIPES. Release the ®. Press and release
the ® pad until the display reads BYPASS OZ/M.
The number represents what the brewer thinks
is the flow rate of the bypass valve in ounces per
minute.
2. If the actual flow rate of the bypass valve is known,
but is different than the number on the display, use
the (-) and (+) pads to enter the correct flow rate
in ounces per minute.
3. When finished, press and release the DONE pad.
This saves the new setting and advances to the
next function screen, CALIBRATE FLOW. Another
alternative is to press the
front switch panel to exit the BYPASS OZ/M func-
tion and return to the MAIN SCREEN.
(+)
P2306
pad located on the
34025 022509

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents