Using the menu-driven display on the front of the brewer, the operator has the ability to alter or modify various
brewing parameters such as brew temperatures, brew volumes, bypass percentages, pulse brew, etc. This allows
for the precise brewing of various flavors of coffee.
Programming of the brewer is achieved by entering a certain function. Then, by the use of the hidden
programming and function pads, the operator can customize the brewing process to their specifications.
To access the programming mode, and to scroll through the different function screens, hidden programming
pads are used. There are five of these pads that will be used for the setup of the brewer.
a) Right Programming (hidden) pad (just to the right of the display): This is used to access the programming
mode, and is also used to scroll forward through the function list.
b) Left Programming (hidden) pad (just to the left of the display): This is used to scroll backwards through the
function list.
c) Digital: This is used to select options that appear on the display during programming.
d) Brewer: This is used to select options that appear on the display during programming.
e) Control: This is used to select options that appear on the display during programming.
UNITS ----------------------------------------------------18
REVIEW/MODIFY/SETUP RECIPE
BREW OZ -------------------------------------------26
% BYPASS ------------------------------------------27
PROGRAMMING
PROGRAMMING SWITCHES
b
READY TO BREW
ENABLE
ON / OFF
WATER TEMP: 200°
BREW
PROGRAMMING SECTION
a
c
d
e
PULSE BREW ---------------------------------------28
DRIP TIME ------------------------------------------32
SET TEMP -----------------------------------------------33
ENABLE ADS --------------------------------------------35
REFILL ---------------------------------------------------40
FLOW RATES --------------------------------------------41
Page 13
ENABLE
ON / OFF
BREW
38112.1 101005