First multicast IP allows to set the first multicast IP address for the network audio
broadcast. Software automatically distribute the address and default is 224.0.6.*. The
multicast IP addresses can neither be the same or conflicted with the address of X-
SMART.
Standby time means the time device automatically shut down the screen and get into
standby status during which there is not any operation. There are 8 options like 10s, 20s
and 30s, etc. can be selected. Default setting is never.
Picture will be shown in the standby window of X-NPMS. The maximum pixel is 339*40.
Click the button
AOD Server IP is used to set the X-SMART server IP address when enable the AOD
function.
Enable Buzzer and Enable General Fault are used to set warning and display the system
fault status.
Show Time & Date is used to display current time.
Delete Temp. Rec. Files and Delete Auto. Rec. Files are used to enable or disable this
function button on the interface.
Extended Key Module Setting
If extended key module X-K4 or X-K8 is used, the type of extend key modules can be chosen from
here. Make sure it must be the same with the actual use. Default setting is none.
Network Setting
Use to set the X-NPMS network parameter. Old IP is the IP address before setting, and New IP is
the IP address after setting. For updating the network parameters of the system devices, it shall be
connected to computer whose IP should be in the same segment with the old IP of X-NPMS.
Click the Update button for setting the IP of X-NPMS, the two IP address would be the same after
updating successfully.
The default IP address is 192.168.2.100. If the specified IP address has been forgotten, the default
IP address can be obtained from device window.
Note: Network parameter is excluded in configuration files. Downloading configuration can't
change network configuration. It can be only changed by updating. While operating, please make
sure device is connected to the network and the network settings are correct.
Storage
Storage status is shown at the bottom of widow to help users understand the space that current
audio files take up. The maximum available capability is 500MB.
REC FTP
This function is unavailable now.
2. Time
"Time" is used to set the requisite parameter for the working clock, as shown below:
Synchronization Mode
"Synchronization Mode" is the function to synchronize the time for X-NPMS through NTP
protocol. Default setting is off.
to select the picture.