Device Settings

The basic function parameters for the X-DCS3000 can be set under this tab. These items such as
Properties, Modules, Amplifier, Time, Supervision, and AVC will be set in turn.
1. Properties
"Properties" is used to set the requisite parameters for the X-DCS3000, as shown below:
Basic Setting
Basic Setting includes Device ID, Device Name, Device Type, Emergency Button and Emergency
Buzzer. Device ID is the only device identification in the system, which in the range of 1~999.
The option "Emergency Button" is to enable or disable emergency button on X-DCS3000 front
panel. The checkbox shown as
Integration Interface
This item is used to set the interface type, which includes Disabled and Dry Contact. The default
setting is disabled.
Network Setting
Use to set the X-DCS3000 network parameter. Old IP is the IP address before setting, and New IP
is the IP address after setting. For updating the network parameters of the system devices, it shall
be connected to computer whose IP should be in the same segment with the old IP of DCS. Click
the Update button for setting the IP of DCS, the two IP address would be the same after updating
successfully. The default IP address is 192.168.2.200. If the specified IP address has been
forgotten, the default IP address can be obtained by pressing the appropriate button to reset the IP
address.
Note: Network parameter is excluded in configuration files. Downloading configuration won't
change network configuration, which can be only changed by updating. While operating, please
make sure device is connected to the network and the network settings are correct.
Zone List
The Zone List setting function allows users to enable/disable the zones and set the Zone Name
and Power. Check the check box shown as
And
shows the zone is disabled. Click directly one zone name or power in the zone list to edit
it. The power setting value is only used to determine if the amplifiers are appropriate. The output
means enabled.
to enable the corresponding zone.