BUNN Espress
A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems
encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic
Technical Service Department at (800) 637-8606.
•
Inspection, testing, and repair of electrical equipment should be performed only by qualified service
personnel.
•
Solenoid removal requires interrupting the water supply to the valve. Damage may result if solenoids are
energized for more than ten minutes without a supply of water.
•
The use of two wrenches is recommended whenever plumbing fittings are tightened or loosened. This will
help to avoid twists and kinks in the tubing.
•
Make certain that all plumbing connections are sealed and electrical connections tight and isolated.
•
This brewer is heated at all times unless disconnected from the power source. Keep away from
combustibles.
•
All electronic components have 208-240 volt ac and low voltage dc potential on their terminals. Shorting
of terminals or the application of external voltages may result in board failure.
•
Intermittent operation of electronic circuit boards is unlikely. Board failure will normally be permanent. If
an intermittent condition is encountered, the cause will likely be a loose connection at a terminal or crimp.
WARNINGS
•
Exercise extreme caution when servicing electrical equipment.
•
Disconnect the brewer from the power source when servicing, except when specified.
•
Follow recommended service procedures.
•
Replace all protective shields and safety notices.
PROBLEM
Equipment will not operate
Brew cycle will not start
TROUBLESHOOTING
®
PROBABLE CAUSE
No power or incorrect voltage
Power switch
No water
Water treatment or strainer
REMEDY
Connect the brewer to the power source.
Check for proper voltage.
Check circuit breaker/fuse.
Must be in the "ON" position.
Power indicator will glow.
Check plumbing and shut off valves.
Direction of flow arrows must be
pointing toward the brewer.
Remove the strainer and/or water
softener and check for obstructions.
Clear or replace.
12