Download Print this page

Troubleshooting - Bunn VPR Operating & Service Manual

Advertisement

PART II / SECTION II
A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems
encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic
Technical Service Department.
Inspection, testing, and repair of electrical equipment should be performed only by qualified service person-
nel.
This brewer is heated at all times. Keep away from combustibles.
WARNING – • Exercise extreme caution when servicing electrical equipment.
• Unplug the brewer when servicing, except when electrical tests are specified.
• Follow recommended service procedures
• Replace all protective shields or safety notices
PROBLEM
Water is not hot
Spitting or excessive steaming

TROUBLESHOOTING

PROBABLE CAUSE
1. Limit Thermostat or Thermal
Cut-Off
CAUTION - Do not eliminate or
bypass limit thermostat/thermal
cut-off. Use only BOM replace-
ment part.
2. Control Thermostat
3. Tank Heater
1. Lime Build-up
CAUTION - Tank and tank com-
ponents should be delimed
regularly depending on local
water conditions. Excessive min-
eral build-up on stainless steel
surfaces can initiate corrosive
reactions resulting in serious
leaks.
2. Control Thermostat
Page 4
REMEDY
Refer to Service - Limit Ther-
mostat or Thermal Cut-Off for
testing procedures. See page 10
or 13
Refer to Service - Control Ther-
mostat for testing procedures.
See page 9
Refer to Service - Tank Heater for
testing procedures. See page 12
Inspect the tank assembly for
excessive lime deposits. Delime
as required.
Refer to Service - Control Ther-
mostat for testing procedures.
Inspect the tank assembly for
excessive lime deposits. Delime
as required.
41667 102708

Advertisement

loading

This manual is also suitable for:

Vps